FarinographTS Auto Calibration Software based torquemixer calibration where
Farinograph-TS Auto. Calibration Software based torque/mixer calibration …where quality is measured. Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
Challenge Ageing process Every Farinograph/Mixer should produce the same results under the same conditions Every device ages differently based on use case, frequency of use, external factors, etc. The typical case is that the customer notices too late that the results differ too much. Of course all old results are questioned here and should be re-validated in the worst case …where quality is measured. 2 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
Goal Increased reproducibility The Auto. Calibration provides a solution to this problem. Through a mathematical curve fitting the ageing is reversed. In the best case, there is no need to send the mixer back and forth. Already 10 years tested, now also available for you …where quality is measured. 3 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
Auto. Calibration How does it work? Master curves can be created from different sources 1. Start AC with MC 2. Perform a ref. measurement 3. Accept calibration model Farino 1 Master curve Apply the master curve to any number of Farinographs Farino 2 OOO 1. Start AC with MC 2. Perform a ref. measurement 3. Replacement / Rental mixer …where quality is measured. 4 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
Auto. Calibration How does it work? Set filter model Apply model Simulates over 10000 measurements Compare with master curve Output of the best result Accept calibration model …where quality is measured. 5 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
Auto. Calibration Your benefits ü The Anti Ageing for your Farinograph/Mixer ü Check quality according to your own standards, at your own interval ü Specified differences can be corrected automatically ü 100% based on real measurements …where quality is measured. 6 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
Auto. Calibration Your benefits ü Works always and everywhere, without cloud connection ü Define your own master instrument and/or reference material ü Calibration on multiple materials are possible ü Calibration model is stored locally inside the mixer …where quality is measured. 7 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
Use cases Starting point: Target tolerances 300 mixer DW: Bandwidth ± 5, 0 FE WZ: Water absorption ± 0, 5 % DDT: Dough development time < 3 min = ± 0, 5 min 3 – 6 min= ± 1, 0 min > 6 min = ± 2, 0 min S: Stability < 4 min = ± 1, 0 min 4 – 10 min = ± 2, 0 min 10 – 20 min = ± 3, 0 min > 20 min = ± 4, 0 min DS: Dough softening < 100 FE ± 20, 0 FE >= 100 FE ± 25, 0 FE …where quality is measured. 8 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
Value proposition What options does Brabender offer? Product Price Correlation Brabender support Incl. reference flours 1 x license bought per device 3, 430 € Required Support can be offered additionally 0 870 € / year Required Includes free advice from the Brabender Customer Service team (phone or e-mail) 2 / year + 580 € Not required Full-service calibration of the device by the Brabender Customer Service 1 / visit 7903013. 100 Yearly subscription 7903013. 200 Integration into current service contracts 7903013. 300 costs will be credited if not successful …where quality is measured. 9 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
How to calibrate Step 1: Press the correlation tile on the homescreen …where quality is measured. 10 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
How to calibrate Step 2: Select automatic calibration option …where quality is measured. 11 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
How to calibrate Step 3: Set calibration parameters …where quality is measured. 12 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
How to calibrate Step 4: Add master curve as target values …where quality is measured. 13 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
How to calibrate Step 5: Set measurement parameters …where quality is measured. 14 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
How to calibrate Step 6: Measurement runs …where quality is measured. 15 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
How to calibrate Step 7: Start calibration …where quality is measured. 16 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
How to calibrate Step 8: Calibration runs Can take up to 30 minutes …where quality is measured. 17 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
How to calibrate Step 9: Results compared to master curve …where quality is measured. 18 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
How to calibrate Step 10: Take filter settings …where quality is measured. 19 Copyright © Brabender® Gmb. H & Co. KG, 10. 03. 2021
- Slides: 19