f Beam Instrumentation Department Instrumentation present and future
f Beam Instrumentation Department Instrumentation -- present and future (Jean’s title) Bob Webber Accelerator Run II Meeting Thursday, January 8, 2004
f Beam Instrumentation Department Instrumentation Priorities – My Perspective • • • • NUMI tasks (struggling to identify the target and really get going) TEV BPMs project (needs increased AD attention) Rapid Transfer Line BPMs (no one presently assigned) Recycler BPM finish-up (just to wrap it up) Pbar Flying Wires (just to get it done) SY-120 (except BPM front-end) Flying Wire and Synch light front-end upgrades (for SDA robustness) Flying Wire performance analysis (on going) BLT standardization and robustification Toroid signal integration and readout upgrades Te. V IPM Accumulator BPM MOOC/ACNET upgrade (MI BPMs hardly even make my list) Tevatron BLM system at some priority (since I first made this list) 1
f Beam Instrumentation Department Organization 2
f Beam Instrumentation Department Responsibilities/Projects 3
f Beam Instrumentation Department Responsibilities/Projects 4
f Beam Instrumentation Department Responsibilities/Projects 5
f Beam Instrumentation Department Responsibilities/Projects 6
f Beam Instrumentation Department Responsibilities/Projects 7
f Beam Instrumentation Department Responsibilities/Projects 8
f Beam Instrumentation Department Responsibilities/Projects 9
f Beam Instrumentation Department Current Activities MI DCCT, toroid electronics MI DCCT, mentoring Spare BPMs BPM, BLM maint. RR, NUMI, and Te. V BPMs, QXR, Temp/Humidity A 1, P 1 BPMs Synch light, BLMs, Flying Wires, SBDs Synch light, BLTs FBIs, DCCTs BLTs, OTR r&d RR BPM, Back Door, Accum BPM SY 120 support, NUMI TLMs, NUMI profile monitors Pbar Flying Wires, Te. V IPM 10
f Beam Instrumentation Department Priorities vs. Assignments • Priorities and current assignment of manpower are not necessarily self-consistent – due to the skill mix and operational maintenance responsibilites of individuals within the Department. • Some projects are not being worked on at the level of effort that task prioritization would indicate appropriate. – That's why you might judge some things in above list as not properly prioritized; they just end up being high priority for persons less well qualified for other things. – Sad but true. 11
f Beam Instrumentation Department Collaborations/Outside Contributors • PPD – Flying wires, multiwires, electronics assembly, synch light, Flying Wire PMT and OTR mechanics • CD – Tev BPM project, Recycler BPMs • University of Texas – NUMI profile monitors • POST-PRESENTATION ADDITIONS: – I failed to acknowledge that the Instrumentation Department also receives critical support and cooperation from the AD Controls, Mechanical Support, and RF Departments – I did mention at the meeting, although not included in these slides, that much instrumentation work is also done to varying degrees by each of the machine systems departments. 12
f Beam Instrumentation Department What Worries Me • NUMI tasks (struggling to identify the target and really get going) • TEV BPMs project (needs increased AD attention) • Rapid Transfer Line BPMs (no one presently assigned) • Pbar Flying Wires (just to get it done) • SY-120 (continued maintenance of disparate systems) • BLT standardization and robustification • Accumulator BPM MOOC/ACNET upgrade • Tevatron BLM system at some priority (since I first made this list) • (MI BPMs hardly even make my list) 13
- Slides: 14