Dawning Information Industry Co Ltd Sugon Infrastructure PUE

  • Slides: 34
Download presentation
Dawning Information Industry Co. , Ltd. Sugon Infrastructure: PUE < 1. 6 Moscow, 12/2015

Dawning Information Industry Co. , Ltd. Sugon Infrastructure: PUE < 1. 6 Moscow, 12/2015

Agenda 2 1 Data Center Overview 2 Cloud. BASE Solutions 3 Liquid-Cooling Server Technology

Agenda 2 1 Data Center Overview 2 Cloud. BASE Solutions 3 Liquid-Cooling Server Technology 4 Successful Stories

Challenges with High-Density Power Consumption of single Cabinet (Unit: KW) Moore's law, the density

Challenges with High-Density Power Consumption of single Cabinet (Unit: KW) Moore's law, the density is higher and higher, heat dissipation, the total power consumption 3

Heat Island Phenomenon The unbalance of the cooling system caused the decrease of MTBF

Heat Island Phenomenon The unbalance of the cooling system caused the decrease of MTBF in the system. Scenario: 1, 100 – 1, 500 W/m² = 3 - 5 k. W / cabinet 4

Data Center Energy Consumption Data Center Power Consumption Source: EYP Mission Critical Facilities Inc.

Data Center Energy Consumption Data Center Power Consumption Source: EYP Mission Critical Facilities Inc. New York Analysis of energy consumption by Mission Critical Facilities EYP, USA 5

PUE: Indicator of data center 6 PUE: Power Usage Effectiveness PUE Value of Typical

PUE: Indicator of data center 6 PUE: Power Usage Effectiveness PUE Value of Typical Data Center Cooling Model Room Level Pool Level Row Level Sugon Product C 2000/C 4000 C 1000/C 3000 Typical PUE 2. 0~2. 4 1. 5~1. 8 1. 4~1. 6

Benefit for Lower PUE 7 Before PUE 1. 6 Input Power IT Load 1,

Benefit for Lower PUE 7 Before PUE 1. 6 Input Power IT Load 1, 000 k. W Price of Power 0. 64 RMB/k. Wh 1, 600 k. W Annual Power Usage 14, 016, 000 k. Wh Annual Cost On Power 8, 970, 240 RMB After PUE 1. 2 Input Power IT Load 1, 000 k. W Price of Power 0. 64 RMB/k. Wh 1, 200 k. W Annual Power Usage 10, 512, 000 k. Wh Annual Cost On Power 6, 727, 680 RMB SAVE! 25% RMB 2. 24 M Before After

1 st Generation Data Center • 1960 s, Science/Technical Computing, Big Machines 8

1 st Generation Data Center • 1960 s, Science/Technical Computing, Big Machines 8

2 nd Generation Data Center • 1990 s, Business Computing, Tower Servers 9

2 nd Generation Data Center • 1990 s, Business Computing, Tower Servers 9

3 rd Generation Data Center • 2000 s, Internet/Communication Industry, Rack Servers 10

3 rd Generation Data Center • 2000 s, Internet/Communication Industry, Rack Servers 10

4 th Generation Data Center • 2010 s, Cloud Computing, Micro Modular Integrated Computer

4 th Generation Data Center • 2010 s, Cloud Computing, Micro Modular Integrated Computer Room 11

Development of Data Center 12 n Hot and cold channel isolation, airflow organized n

Development of Data Center 12 n Hot and cold channel isolation, airflow organized n Exact nearby air, circulating air resistance, low fan power n The level of air, solve the cabinet vertical temperature gradient n Increase supplied air temperature and reduce power consumption n For refrigeration equipment, without excessive cooling room 机柜级 Rack Level 机柜排级 机柜池级 Pool Level 机房级 Room Lever Row Level

Agenda 13 1 Data Center Overview 2 Sugon Cloud. BASE Solutions 3 Liquid-Cooling Server

Agenda 13 1 Data Center Overview 2 Sugon Cloud. BASE Solutions 3 Liquid-Cooling Server Technology 4 Successful Stories

Green IT Infrastructure 14 Step PUE from 2. 2 to 1. 2 Server-Level Cabinet-Level

Green IT Infrastructure 14 Step PUE from 2. 2 to 1. 2 Server-Level Cabinet-Level Micro Module Level Room Level Liquid-cooling Server Liquid-cooling Workstation Cabinet, Power supplement, Cooling, Monitoring Green. Row Module Green. Pool Module Plan & Design Evaluation & Reform

Cloud. BASE Serials Mode 15 In-row Hot Pool Cold Pool Fluorine Cooling Refrigerant 410

Cloud. BASE Serials Mode 15 In-row Hot Pool Cold Pool Fluorine Cooling Refrigerant 410 a C 1000 C 2000 -H Water Cooling C 3000 C 4000 -H cooling capacity Per Cabinet 8~30 KW 3~8 KW 10~30 KW Low density Computing, especially for Designed for large scale High Air Flow High density Computing, such as Scenarios HPC(High performance computing), large data center the pre-installed Cabinet system Performance Computing

Selection of Cloud. BASE Solutions 16 Room Level PUE 2. 0~2. 4 Scale of

Selection of Cloud. BASE Solutions 16 Room Level PUE 2. 0~2. 4 Scale of Data Center Initial Cost + Maintain Cost Pool Level PUE 1. 5~1. 8 Row Level PUE 1. 4~1. 6 Maintain Cost Power Density Initial Cost Operating Time

Row-level Solutions (C 1000/C 3000) -External compressor, reducing machine vibration impact on IT equipment

Row-level Solutions (C 1000/C 3000) -External compressor, reducing machine vibration impact on IT equipment - Compressor N + 1 redundancy, where 1 is the inverter compressor station can dynamically adjust the amount of refrigerant -Refrigerant pipe length 80 meters maximum range, far higher than traditional precision air conditioning, reduce space constraints 17

Large Scale Solutions Larger Scale system can be combined TC 5600 with Cloud. BASE

Large Scale Solutions Larger Scale system can be combined TC 5600 with Cloud. BASE C 2000 pool level cooling system to achieve mass deployment Supercomputer Center PUE≤ 1. 5, effectively droping TCO costs 18 Large Scale Solution

Water-cooling Chiller with Natural cooling Solution T≤ 5℃ Full Natural Wind Cooling 5℃<T≤ 13℃

Water-cooling Chiller with Natural cooling Solution T≤ 5℃ Full Natural Wind Cooling 5℃<T≤ 13℃ Part of Natural Wind Cooling T> 13℃ Air Conditioner Cooling Water-cooling chillers with natural wind cooling energy-saving module In winter, chiller refrigeration compressor open alternative drycooler to provide chilled water for the air-conditioning machine 19

Sugon Cabinets 20 C 200 / C 1000 / C 2000 / C 3000

Sugon Cabinets 20 C 200 / C 1000 / C 2000 / C 3000 Cabinet uniform appearance Aluminum-magnesium alloy cabinet profiles Light weight, high strength, static bearing 1000 kg Top -mounted integrated strength of the wire groove Electric access door and smoke automatic door

Advantage of Sugon Cloud. BASE Solutions High Density Green IT High Avaliability Smart •

Advantage of Sugon Cloud. BASE Solutions High Density Green IT High Avaliability Smart • Channel closed, the level of air, hot and cold air isolation order, improve the cooling efficiency • The level of air, the nearest refrigeration, air-conditioning return air temperatures increase, lower energy efficiency • Two kinds of chilled water and freon refrigeration systems, support winter natural cooling technology • Modular design, flexible deployment, adaptation stage partition construction • Total solutions • Intelligent engine room centralized management, IT and "IT microenvironment" unified infrastructure management platform Standard • Engineering products of the factory completion of the inspection, site integration Integration. Implemetation period is shortened by 20% to 30% Advanced • 4 th generation data center concept • Optimization of energy consumption indicators PUE, saving 15% to 20%, saving space by 30% to 40% 21

Agenda 22 1 Data Center Overview 2 Sugon Cloud. BASE Solutions 3 Liquid-Cooling Server

Agenda 22 1 Data Center Overview 2 Sugon Cloud. BASE Solutions 3 Liquid-Cooling Server Technology 4 Successful Stories

Liquid Cooling Servers n TC 4600 -LP ü 5 U 10 Blade ü Intel

Liquid Cooling Servers n TC 4600 -LP ü 5 U 10 Blade ü Intel Xeon E 5 -2600 V 2/V 3 ü PCIe 3. 0 FDR 56 Gb/s Infini. Band n Advanced ü More power saving: Fans 70%, Air Conditioner 80% ü More Reliability: Reduce the temperature of processor by 20℃ ü Low Noise: Reduce the noise by 10 d. B ü Higher Performance: Up to 5% with overclocking 23

Immersion cooling workstation W 560 -LI n Feature n Silicone Media n Immersion cooling

Immersion cooling workstation W 560 -LI n Feature n Silicone Media n Immersion cooling technology n Fanless design n Advantage n n n Ultra Low Noise: 35 d. B High reliability dust-proof Moistureproof Anti-salt spray Anti-sulfide 24

Agenda 25 1 Data Center Overview 2 Sugon Cloud. BASE Solutions 3 Liquid-Cooling Server

Agenda 25 1 Data Center Overview 2 Sugon Cloud. BASE Solutions 3 Liquid-Cooling Server Technology 4 Successful Stories

Some Successful Stories in Infrastructure Field 26

Some Successful Stories in Infrastructure Field 26

Magic Cube (TC 5000 A, 2008) Rank No. 10 th 3840 2 -way TC

Magic Cube (TC 5000 A, 2008) Rank No. 10 th 3840 2 -way TC 2600 First Chinese-designed Blade Infini. Band interconnection Peak Perf. : 233. 5 Tflops The Largest Window HPC in the World 27

Dawning 6000 (2010) No. 1 st theoretical peak performance, No. 2 nd in Linpack

Dawning 6000 (2010) No. 1 st theoretical peak performance, No. 2 nd in Linpack performance , 5500 2 -way TC 3600, NVidia C 2050, Infini. Band, 2. 98 Pflops First Intel SSI architecture Blade Server the largest CPU+GPU supercomputer in the world 28

Land. Ocean Beijing Processing Center 29 600 square meters of room area, installed capacity

Land. Ocean Beijing Processing Center 29 600 square meters of room area, installed capacity of 1 MW C 3000 row-level solution for CPU&GPU Computing Region C 4000 hot-pool solution for Storage Region T≤ 5℃ Full Natural Wind Cooling 5℃<T≤ 13℃ Part of Natural Wind Cooling Natural Cooling Technology, PUE<1. 4 T> 13℃ Air Conditioner Cooling - 42* 30 KW Liquid-cooling in-row air conditioners - 40* High-density Isolated Cabinet - 26* Normal Cabinets - 2* 550 KW Natural cooling water chiller unit - 1* Suit of Power Supplement & IMMS

Land. Ocean Beijing Processing Center 30

Land. Ocean Beijing Processing Center 30

Land. Ocean Beijing Processing Center 31

Land. Ocean Beijing Processing Center 31

Chengdu & Nanjing Cloud Computing Center 1 st period, 2009, 300 servers 1 st

Chengdu & Nanjing Cloud Computing Center 1 st period, 2009, 300 servers 1 st period, 2012, 1000 servers 32

Wuxi City Cloud Center Constructed in 2011, 5000 servers, public cloud service 33

Wuxi City Cloud Center Constructed in 2011, 5000 servers, public cloud service 33

THANKS ADDRESS: Sugon Building, No. 36 Zhongguancun Software Park, No. 8 Dongbeiwang West Road

THANKS ADDRESS: Sugon Building, No. 36 Zhongguancun Software Park, No. 8 Dongbeiwang West Road Haidian District, 100094, Beijing, P. R. China TELEPHONE: 86 -10 -56308000 WWW :http: //www. sugon. com Weibo:http: //weibo. com/zksugon