Objectives • Familiarize you with the options for controlling electrical heat-tracing systems • Familiarize

Objectives • Familiarize you with the options for controlling electrical heat-tracing systems • Familiarize you with the different methods of monitoring electrical heat-tracing systems • Provide an overview of TTC’s products for control and monitoring 3

Summary XL-Trace Freeze protection Self-Regulating, Ambient & Line Sensing Thermostats, Digi. Trace 910 Electro.

Summary XL-Trace Freeze protection Self-Regulating, Ambient & Line Sensing Thermostats, Digi. Trace 910 Electro. Melt, Ice. Stop Snow and Ice Melting Manual, Ambient Thermostat, Building DCS, Snow Controller Ray. Sol Floor Heating Manual or Timed, Floor. Sensing Thermostat, Digi. Trace 910 HWAT Hot Water Maintenance Self-Regulating, Line Sensing Control? 4

Control and Monitoring are Different Control Monitoring • Control – Varying the heating cable

Control and Monitoring are Different Control Monitoring • Control – Varying the heating cable output to achieve the desired temperature • Monitoring – Providing feedback on the status of the heat-traced system 5

Options for XL-Trace • Self-Regulating • Ambient sensing control – Ambient sensing thermostats •

Options for XL-Trace • Self-Regulating • Ambient sensing control – Ambient sensing thermostats • Line sensing control – Line sensing thermostats • Monitoring & Control with Digi. Trace 910 6

Self-Regulating Control is Simple Distribution Panel Power Connection Heating cable End Seal 7

Self-Regulating Control is Simple Distribution Panel Power Connection Heating cable End Seal 7

Ambient Sensing Control Main Contactor Distribution Panel Ambient sensing thermostat 8

Ambient Sensing Control Main Contactor Distribution Panel Ambient sensing thermostat 8

Ambient Sensing Thermostats Fixed 40°F setpoint AMC-1 A AMC-F 5 9

Ambient Sensing Thermostats Fixed 40°F setpoint AMC-1 A AMC-F 5 9

Line Sensing Control Distribution Panel Line sensing thermostat or Digitrace 910 10

Line Sensing Control Distribution Panel Line sensing thermostat or Digitrace 910 10

Line Sensing Thermostats Fixed 40°F setpoint AMC-1 B AMC-F 5 11

Line Sensing Thermostats Fixed 40°F setpoint AMC-1 B AMC-F 5 11

Ground-Fault Monitoring • • Advantages – Monitors integrity of heating cable and power distribution

Ground-Fault Monitoring • • Advantages – Monitors integrity of heating cable and power distribution wiring – Readily available equipment – Low installed cost Disadvantages – Monitors cable integrity, not performance – Required bell alarm contract on GFPD 12

Monitoring Using GFPD Distribution Panel Power Connection Heating cable End Seal GFPD 13

Monitoring Using GFPD Distribution Panel Power Connection Heating cable End Seal GFPD 13

Digi. Trace 910 • • • 910 Single point electronic controller (920 Multi-point) Approved

Digi. Trace 910 • • • 910 Single point electronic controller (920 Multi-point) Approved GFPD replaces t-stat and ground fault breaker Compatible with BMS, Networkable Provides temperature, current and ground fault monitoring Order RTD separately 14

Temperature Monitoring • • Advantages – Measures performance (will it freeze? ) – Provides

Temperature Monitoring • • Advantages – Measures performance (will it freeze? ) – Provides extensive alarm capability - Low and high temperature - High Low Amps - High Ground fault & Ground Fault trip – Can be networked to each other & a PC Disadvantages – Expensive to install on each circuit 15

Temperature Monitoring w/910 Distribution Panel W/ Standard Circuit Breaker Digi. Trace 910 RTD 16

Temperature Monitoring w/910 Distribution Panel W/ Standard Circuit Breaker Digi. Trace 910 RTD 16

Control for Electro. Melt and Icestop • • Manual Control (on/off control switched by

Control for Electro. Melt and Icestop • • Manual Control (on/off control switched by hand) Ambient-sensing control - AMC-F 5, AMC-1 A Automated Building Management System (on/off control switched by building computer) Automatic snow controllers (on/off control based on temperature and moisture) - Controllers - APS-4 (208 -240), APS-4 (277), APS - -3 B Sensors - CIT-1, GIT-1, SIT-1 17

Product Offering APS-4 GIT-3 APS-3 B RCU-1 GIT-1 CIT-1 LCD-1 SIT-5 E SC-40 18

Product Offering APS-4 GIT-3 APS-3 B RCU-1 GIT-1 CIT-1 LCD-1 SIT-5 E SC-40 18

Manual Control Main Contactor Distribution Panel w/GFPD’s Simple Switch 19

Manual Control Main Contactor Distribution Panel w/GFPD’s Simple Switch 19

Ambient Control Main Contactor Distribution Panel w/GFPD’s Ambient sensing thermostat single circuit control 20

Ambient Control Main Contactor Distribution Panel w/GFPD’s Ambient sensing thermostat single circuit control 20

Building Management System Main Contactor Distribution Panel w/GFPD’s Building Management System 21

Building Management System Main Contactor Distribution Panel w/GFPD’s Building Management System 21

Automatic Snow Controller • • Automatically turns on system at 38°F with the presence

Automatic Snow Controller • • Automatically turns on system at 38°F with the presence of moisture Variable hold-on time after snowfall ends Manual override In-pavement sensor available 22

Automatic Snow Controller Main Contactor Distribution Panel w/GFPD’s APS-3 B Snow Controller CIT-1 pole

Automatic Snow Controller Main Contactor Distribution Panel w/GFPD’s APS-3 B Snow Controller CIT-1 pole mounted sensor SIT-1 pavement mounted sensor 23

Ice. Stop Control Main Contactor GIT-1 gutter mounted sensors Distribution Panel APS-4 Snow Controller

Ice. Stop Control Main Contactor GIT-1 gutter mounted sensors Distribution Panel APS-4 Snow Controller CIT-1 pole mounted sensor 24

Control and Monitoring For Ray. Sol • Manual or Timed Control • Floor Temperature

Control and Monitoring For Ray. Sol • Manual or Timed Control • Floor Temperature Sensing Control and Monitoring 25

Manual or Timed Control Main Contactor Distribution Panel w/GFPD’s Simple switch or timed switch

Manual or Timed Control Main Contactor Distribution Panel w/GFPD’s Simple switch or timed switch 26

Floor Temperature Sensing Control Main Contactor Distribution Panel w/GFPD’s FWT-2 E Floorstat FWT-3 27

Floor Temperature Sensing Control Main Contactor Distribution Panel w/GFPD’s FWT-2 E Floorstat FWT-3 27

Floor Control and Monitoring Main Contactor Digi. Trace 910 Distribution Panel w/GFPD’s 28

Floor Control and Monitoring Main Contactor Digi. Trace 910 Distribution Panel w/GFPD’s 28

Monitoring and Control for HWAT? • Self-Regulating control • Line Sensing Control? 29

Monitoring and Control for HWAT? • Self-Regulating control • Line Sensing Control? 29

HWAT Line Sensing Control? Digi. Trace 910 Locate sensor on “dead-leg” 30