Compressor Replacement – ODU Outdoor unit – Remove IDU & ODU Connecting pipe Accessory

Compressor Replacement – ODU Outdoor unit – Remove IDU & ODU Connecting pipe Accessory Remove Control Board Cover plate ( 1 Screw) & Disconnect the IDU & ODU Connection. Remove the locking Screws of Valve Side plate (8 Screw) Open the Discharge Valve to release the Refrigerant from AC completely Remove the locking Screws of Top cover (8 Screw) Remove the locking Screws of Front plate (7 Screw) 0

Compressor Replacement – ODU Remove Control Board & its Wiring (Motor & Compressor Wiring).

Compressor Replacement – ODU Remove Control Board & its Wiring (Motor & Compressor Wiring). De-braze Suction & Discharge Tube. Take Out Control Board & Change The Capacitor AS Required Value (As per Requirement)(OLD Capacitor 40+2. 5 Mfd, new Capacitor – 50+2. 5 Mfd ) Remove screw of suction valve from valve plate to remove suction tube assy. Take new Compressor For Replacement. OLD Comp – UR 8 B 180 JHCJH NEW Comp – UR 8 B 180 DUBJH Remove the Wiring connection of compressor. Remove Compressor Mounting Nut & Take Out the Compressor Use Same Compressor Accessory to Fit The new Compressor As Shown. 1

Compressor Replacement – ODU Braze the Discharge & Suction Tube. Fix The Suction Valve

Compressor Replacement – ODU Braze the Discharge & Suction Tube. Fix The Suction Valve With Valve plate. Do the Compressor Wiring. ØVacuum the system and Gas charge ( Qty refer to Quality Label) Ø Check all the joints with soap solution ØAssemble the components in reverse order 2