Clarity Chromatography Software Clarity 3 0 New features

  • Slides: 25
Download presentation
Clarity Chromatography Software Clarity 3. 0 – New features page: 1 Code: P 021/30

Clarity Chromatography Software Clarity 3. 0 – New features page: 1 Code: P 021/30 A Date: 26. 2. 2010

More than 100 new features in version 3. 0 § Calibration § Import/Export §

More than 100 new features in version 3. 0 § Calibration § Import/Export § Chromatogram § Event table § User Interface § Reports § Sequence page: 2 Code: P 021/30 A Date: 26. 2. 2010

Opening the Clarity Instrument § Option to select project in Login Dialog § Auto

Opening the Clarity Instrument § Option to select project in Login Dialog § Auto Lock - option to lock Instrument after predefined period Select your Project during the logon page: 3 Code: P 021/30 A Date: 26. 2. 2010

Improvements in user interface § User Options - new tab Directories to set paths

Improvements in user interface § User Options - new tab Directories to set paths for PDF reports, exports and imports § Tables - function Fill series (Sequence, Calibration, Gradient) page: 4 Code: P 021/30 A Date: 26. 2. 2010

Calibration § Bracketing, Standard Addition, Normalization § Improved Identification Windows § Forced Compound Identification

Calibration § Bracketing, Standard Addition, Normalization § Improved Identification Windows § Forced Compound Identification § New Calibration curves, Linearization of Calibration Graph Axes § Calculation by Response of Another Compound § Response factor as Amount/Response or Response/Amount § Response Correction Factor page: 5 Code: P 021/30 A Date: 26. 2. 2010

Calibration Options Calibration curve check Failure displayed in the Peak Type column in Result

Calibration Options Calibration curve check Failure displayed in the Peak Type column in Result Table New Calculation types NORM STDADD page: 6 Code: P 021/30 A Date: 26. 2. 2010

Linearization of axes in Calibration Show linearized values in Graph Properties Select appropriate function

Linearization of axes in Calibration Show linearized values in Graph Properties Select appropriate function to linearize the values on X, Y axes page: 7 Code: P 021/30 A Date: 26. 2. 2010

New Curve Fit Types in Calibration Select a new curve: • ln • log

New Curve Fit Types in Calibration Select a new curve: • ln • log 10 • exp • pow 10 • Hyperbola • Half Sigmoid page: 8 Code: P 021/30 A Date: 26. 2. 2010

Chromatogram § User columns – compound name in special values § Mathematical operations –

Chromatogram § User columns – compound name in special values § Mathematical operations – invert function to reverse polarity § Advanced peak tags § File open dialog – option to change overlay mode § Result table – peak type indicates more info § Support for electronic signatures in PDF reports page: 9 Code: P 021/30 A Date: 26. 2. 2010

Enhanced Peak Type info Ordnr/Ref/ISTD/RISTD/GRP Error (Curve Check) <LOD and<LOQ (Forced) (by name) (CF)

Enhanced Peak Type info Ordnr/Ref/ISTD/RISTD/GRP Error (Curve Check) <LOD and<LOQ (Forced) (by name) (CF) peak type value could not be calculated calibration curve does not met preset criteria value lower then set limits identification forced by integration table another compound calibration data used correction factor in calibration applied Peak Type in Result Table indicates used calibration options page: 10 Code: P 021/30 A Date: 26. 2. 2010

Overlay mode Change to Overlay mode in Open Chromatogram dialog page: 11 Code: P

Overlay mode Change to Overlay mode in Open Chromatogram dialog page: 11 Code: P 021/30 A Date: 26. 2. 2010

Electronic signatures in PDF reports page: 12 Code: P 021/30 A Date: 26. 2.

Electronic signatures in PDF reports page: 12 Code: P 021/30 A Date: 26. 2. 2010

Force Peak Identification § Name peaks without calibration file § Override identification by calibration

Force Peak Identification § Name peaks without calibration file § Override identification by calibration Force Peak Identification Select new Peak Identification Select Peak to Force page: 13 Code: P 021/30 A Date: 26. 2. 2010

Relative Retention Times Force Peak Identification Calculated RRT page: 14 Code: P 021/30 A

Relative Retention Times Force Peak Identification Calculated RRT page: 14 Code: P 021/30 A Date: 26. 2. 2010 Setup User Column using the Special Values, Compound option

Customizable order of Report Sections Right click the tab and adjust its position page:

Customizable order of Report Sections Right click the tab and adjust its position page: 15 Code: P 021/30 A Date: 26. 2. 2010

Export of graphs § Export of graphs from PDA view § Export Calibration curve

Export of graphs § Export of graphs from PDA view § Export Calibration curve as picture page: 16 Code: P 021/30 A Date: 26. 2. 2010

Export of data in Excel (. xls) format page: 17 Code: P 021/30 A

Export of data in Excel (. xls) format page: 17 Code: P 021/30 A Date: 26. 2. 2010

Import Chromatogram Data Store your preferences for future use (user specific) Apply same settings

Import Chromatogram Data Store your preferences for future use (user specific) Apply same settings to multiple files opened simultaneously Import of multiple signal chromatogram data aranged in columns Preview the imported data file page: 18 Code: P 021/30 A Date: 26. 2. 2010

Event table § Events could be performed outside run § New input conditions §

Event table § Events could be performed outside run § New input conditions § New output actions § Resizable dialog and columns width New set of event for running/idle state of Instrument page: 19 Code: P 021/30 A New set of commands in Output Date: 26. 2. 2010

Valve control Set custom position for Valve at Close Instrument Input/Output names instead of

Valve control Set custom position for Valve at Close Instrument Input/Output names instead of numbers page: 20 Code: P 021/30 A Date: 26. 2. 2010

Sequence Bypass to perform run without injection for startup and shutdown methods New columns:

Sequence Bypass to perform run without injection for startup and shutdown methods New columns: • Include in SST – perform SST test when injection is finished • Stored Calib. – chromatogram will be opened with stored calibration • Close All – close all currently opened chromatograms in overlay to prepare for next summary report New file name variables %P – Project %s – Sequence %J – Method page: 21 Code: P 021/30 A Date: 26. 2. 2010

Bracketing and Standard Addition This calibration will be used with Calibration used as specified

Bracketing and Standard Addition This calibration will be used with Calibration used as specified by user Copy of the Example Calibration will be created according to Sequence options, Calibration and Sequence Usage page: 22 Code: P 021/30 A Calibration and Sequence Usage Clone calibration at each Sequence start Standard Addition Bracketing Date: 26. 2. 2010

Extension and Control Modules § PDA – option Add All Identified Peaks to Spectrum

Extension and Control Modules § PDA – option Add All Identified Peaks to Spectrum library § FC GP – new option Collect all § Flow rate units options extended to L/min, m. L/min, µL/min page: 23 Code: P 021/30 A Date: 26. 2. 2010

Control Modules in development § Agilent 7890 GC § Agilent 1200 HPLC DAD (G

Control Modules in development § Agilent 7890 GC § Agilent 1200 HPLC DAD (G 1315 D) § Sedere ELSD detector 80 LT and 85 LT § PG Instruments LC-200 HPLC page: 24 Code: P 021/30 A Date: 26. 2. 2010

For more information please visit our website: § What‘s new ( menu: Products –

For more information please visit our website: § What‘s new ( menu: Products – Clarity – Next steps – What is new) § Preliminary Demo version ( menu: Downloads – Preliminary versions) § Preliminary version ( menu: Downloads – Preliminary versions) page: 25 Code: P 021/30 A Date: 26. 2. 2010