Chapter Analog Inputs and Outputs Continuous Inputs Continuous













- Slides: 13
Chapter - Analog Inputs and Outputs Continuous Inputs Continuous Outputs
Sampled Data
Actual Inputs
Relationships
Example
Aliasing
Analog Output Relationships
Example
Analog IO Control Registers rack: 2: C. Ch 0 Safe. State. Config - Sets the safe state when the module update fails rack: 2: C. Ch 1 Safe. State. Config - Sets the safe state when the module update fails rack: 2: C. Ch 0 Input. Full. Range - 0 = 4 -20 m. A; 1 = -10 -10 V, 0 -20 m. A rack: 2: C. Ch 1 Input. Full. Range - 0 = 4 -20 m. A; 1 = -10 -10 V, 0 -20 m. A rack: 2: C. Ch 2 Input. Full. Range - 0 = 4 -20 m. A; 1 = -10 -10 V, 0 -20 m. A rack: 2: C. Ch 3 Input. Full. Range - 0 = 4 -20 m. A; 1 = -10 -10 V, 0 -20 m. A rack: 2: C. Ch 0 Outut. Full. Range - 0 = 4 -20 m. A; 1 = -10 -10 V, 0 -20 m. A rack: 2: C. Ch 1 Output. Full. Range - 0 = 4 -20 m. A; 1 = -10 -10 V, 0 -20 m. A rack: 2: C. Ch 0 Input. Config. Select - 0 = 0 -10 V, 0 -20 m. A; 1 = 4 -20 m. A, -10 V rack: 2: C. Ch 1 Input. Config. Select - 0 = 0 -10 V, 0 -20 m. A; 1 = 4 -20 m. A, -10 V rack: 2: C. Ch 2 Input. Config. Select - 0 = 0 -10 V, 0 -20 m. A; 1 = 4 -20 m. A, -10 V rack: 2: C. Ch 3 Input. Config. Select - 0 = 0 -10 V, 0 -20 m. A; 1 = 4 -20 m. A, -10 V rack: 2: C. Ch 0 Output. Config. Select - 0 = 0 -10 V, 0 -20 m. A; 1 = 4 -20 m. A, -10 V rack: 2: C. Ch 1 Output. Config. Select - 0 = 0 -10 V, 0 -20 m. A; 1 = 4 -20 m. A, -10 V rack: 2: C. SSCh 0 Output. Data - A safe output value for channel 0 rack: 2: C. SSCh 1 Output. Data - A safe output value for channel 1
Analog Input / Output Registers rack: 2: I. Fault - Returns a fault code for the module rack: 2: I. Ch 0 Input. Data - The analog input value read on channel 0 rack: 2: I. Ch 1 Input. Data - The analog input value read on channel 1 rack: 2: I. Ch 2 Input. Data - The analog input value read on channel 2 rack: 2: I. Ch 3 Input. Data - The analog input value read on channel 3 rack: 2: I. Ch 0 Input. Underrange - The channel 0 current is below 4 m. A rack: 2: I. Ch 1 Input. Underrange - The channel 1 current is below 4 m. A rack: 2: I. Ch 2 Input. Underrange - The channel 2 current is below 4 m. A rack: 2: I. Ch 3 Input. Underrange - The channel 3 current is below 4 m. A rack: 2: I. Ch 0 Output. Open. Wire - The output current is zero - indicates broken wire rack: 2: I. Ch 1 Output. Open. Wire - The output current is zero - indicates broken wire rack: 2: I. Power. Up - The module is configured and running normally rack: 2: O. Ch 0 Output. Data - The analog output voltage for channel 0 rack: 2: O. Ch 1 Output. Data - The analog output voltage for channel 1
An Example
Pulse Width Modulation (PWM)
Shielding