Burst ICW System Subject: Date: From: To: CC: RE: M-Test/Mu. Cool Freeze Damage Repair Estimate Thu, 19 Apr 2018 11: 48: 24 -0500 Gregory S Gilbert <gilbert@fnal. gov> Benjamin J Hansen <bhansen@fnal. gov> Larry T Sliwa <lsliwa@fnal. gov>, John P. Pollock <pollockj@fnal. gov>, Lonnie R. Huitt <lhuitt@fnal. gov>, Glen E Smith <gesmi@fnal. gov>, Steven L. Shirley <shirley@fnal. gov>, Allen R Schmitt <aschmitt@fnal. gov>, Paul C Czarapata <pcceed@fnal. gov>, Brian K. Petersohn <petersohn@fnal. gov> Ben: Here are the quotes for replacement of the Fulflo Filters. The original filters are obsolete, replacements are $2313. 33 ea. X 4 = $9253. 20. So low end for strainer materials and sprinkler repairs would be: 1 ea. 4” Cast Iron Adams Strainer $13, 991. 00 4 ea. Fulflo Filters 9, 253. 20 Sprinkler Repairs $12, 000. 00 Total $35, 244. 20 Damaged equipment: • Fire sprinklers • ICW filters • Stainless fulflo filters Estimated cost: ~$60 k The high end would be an additional $25, 000 for complete Sprinkler replacement and the Stainless Adams Strainer, which FESS would recommend. This does not include any labor for the Adams Strainer or Fulflo Filter Replacements. Regards, Greg 8 May, 2018 1
1 m Irradiation Station (conceptual) concrete BEAM BBEAMEA test device goes here 6” ID 8 May, 2018 2
What follows is a summary of Jason’s studies 8 May, 2018 3
Residual Dose 12 hr irradiation @ 5× 1012 protons/s 1 hr cool down “Test” Materials Si: 0. 9 cm thick (10% X 0) , 15 cm radius Si: 4. 65 cm thick (10% λ) , 15 cm radius Fe: 45 cm thick, 15 cm radius 0. 18 m. Rem/hr 0. 70 m. Rem/hr 5. 4 m. Rem/hr 6. 1 m. Rem/hr 6. 3 m. Rem/hr 31 m. Rem/hr 8 May, 2018 4
Residual Dose 12 hr irradiation @ 5× 1012 protons/s 1 day cool down 0. 057 m. Rem/hr 0. 12 m. Rem/hr 1. 2 m. Rem/hr 0. 96 m. Rem/hr 0. 97 m. Rem/hr 5. 0 m. Rem/hr 8 May, 2018 5
Residual Dose 12 hr irradiation @ 5× 1012 protons/s 1 hr cool down “Test” Materials Si: 0. 9 cm thick (10% X 0) , 15 cm radius Si: 4. 65 cm thick (10% λ) , 15 cm radius Fe: 45 cm thick, 15 cm radius 544 m. Rem/hr 487 m. Rem/hr 426 m. Rem/hr 108 m. Rem/hr 102 m. Rem/hr 1870 m. Rem/hr 443 m. Rem/hr 452 m. Rem/hr 2370 m. Rem/hr 8 May, 2018 6
Residual Dose 12 hr irradiation @ 5× 1012 protons/s 1 week cool down “Test” Materials Si: 0. 9 cm thick (10% X 0) , 15 cm radius Si: 4. 65 cm thick (10% λ) , 15 cm radius Fe: 45 cm thick, 15 cm radius 1. 8 m. Rem/hr 1. 6 m. Rem/hr 1. 1 m. Rem/hr 0. 15 m. Rem/hr 0. 14 m. Rem/hr 2. 3 m. Rem/hr 1. 2 m. Rem/hr 1. 3 m. Rem/hr 4. 6 m. Rem/hr 8 May, 2018 7
Residual Dose 1016 POT once per week for 52 weeks 1 week cool down “Test” Materials Si: 0. 9 cm thick (10% X 0) , 15 cm radius Si: 4. 65 cm thick (10% λ) , 15 cm radius Fe: 45 cm thick, 15 cm radius 7090 m. Rem/hr 6680 m. Rem/hr 7. 28 m. Rem/hr 14. 1 m. Rem/hr 13. 4 m. Rem/hr 5. 9 m. Rem/hr 8 May, 2018 may impact groundwater 8