Avoiding Matrix Interferences in Ion Chromatography Using Solid Phase Extraction Alltech Associates, Inc. Brandstraat

Avoiding Matrix Interferences in Ion Chromatography Using Solid Phase Extraction Alltech Associates, Inc. Brandstraat 12, 9160 Lokeren Phone: 09 340 65 65 • Web Site: www. alltechweb. com a Grace company

Types of Sample Matrix Interferences in Ion Chromatography • Samples with components that will

Types of Sample Matrix Interferences in Ion Chromatography • Samples with components that will damage the column. • Samples that are too acidic for cation analysis. • Samples that are too basic for anion analysis. • Samples that contain high concentrations of interfering ions. a Grace company

Problems with Common Sample Preparation Techniques Dilution and Filtration are not suitable when: •

Problems with Common Sample Preparation Techniques Dilution and Filtration are not suitable when: • The analytes are present at trace levels. • The analytes differ greatly in concentration. • soluble. Interfering compounds and analytes are both a Grace company

Solid Phase Extraction (SPE) Cartridges for Ion Chromatography • Stable from p. H 2

Solid Phase Extraction (SPE) Cartridges for Ion Chromatography • Stable from p. H 2 to 13. • Low IC interference levels. • Requires only 2 - 3 m. L of samples. a Grace company

The Alltech Maxi-Clean™ IC Cartridge Construction Polypropylene Housing Packing Material Female Luer Inlet Male

The Alltech Maxi-Clean™ IC Cartridge Construction Polypropylene Housing Packing Material Female Luer Inlet Male Luer Outlet Polyethylene Frits a Grace company

Types of Maxi-Clean™ IC SPE Cartridges: • Maxi-Clean™ IC-RP • Maxi-Clean™ IC-Ag • Maxi-Clean™

Types of Maxi-Clean™ IC SPE Cartridges: • Maxi-Clean™ IC-RP • Maxi-Clean™ IC-Ag • Maxi-Clean™ IC-Ba • Maxi-Clean™ IC-OH • Maxi-Clean™ IC-Na • Maxi-Clean™ IC-Chelate a Grace company

General Procedure for Using Maxi-Clean™ IC Cartridges 1. Precondition the cartridge by passing 5

General Procedure for Using Maxi-Clean™ IC Cartridges 1. Precondition the cartridge by passing 5 -10 m. L of IC grade water (use 5 m. L of methanol followed by 5 m. L of Water for Maxi-Clean™ IC-RP). 2. Load the sample at a rate of 1 m. L/min or less. (Adjust the sample size to use 50% or less of the device’s capacity). 3. Discard the first 1 m. L eluate. 4. Collect and analyze the remaining eluate. a Grace company

Maxi-Clean™ IC-RP Product Specifications Packing: Polystyrene Particle Size: 300µm Retains: Hydrophobic components by a

Maxi-Clean™ IC-RP Product Specifications Packing: Polystyrene Particle Size: 300µm Retains: Hydrophobic components by a reversed-phase mechanism Applications: Removal of hydrophobic organic components a Grace company

Maxi-Clean™ IC-RP Removes Organic Contaminants 5351 Trace Anions in Aniline 1. Chloride 2. Nitrate

Maxi-Clean™ IC-RP Removes Organic Contaminants 5351 Trace Anions in Aniline 1. Chloride 2. Nitrate 3. Sulfate Column: Mobile Phase: Flowrate: Detector: Original Sample a Grace company After Cleanup with Maxi-Clean™ IC-RP Anion/S, 250 x 4. 1 mm 4 m. M KHP p. H 4. 5 2. 0 m. L/min Alltech Conductivity

Average % Recovery of Ions with Maxi-Clean™ IC-RP Cartridge a Grace company

Average % Recovery of Ions with Maxi-Clean™ IC-RP Cartridge a Grace company

Sample Preparation by Precipitation Maxi-Clean. TM IC-Ba • to analysis For removal of sulfate

Sample Preparation by Precipitation Maxi-Clean. TM IC-Ba • to analysis For removal of sulfate and phosphate prior Resin-2 -Ba+2 + M+2 SO 4 -2 Ba+2 SO 4 -2 Resin-2 -M+2 + Maxi-Clean. TM IC-Ag • For removal of halides prior to analysis Resin--Ag+ + M+X- M=Sample cations X= Cl-, Br-, I- a Grace company Resin--M+ + Ag+X-

The Solubility of Barium and Silver Salts in Aqueous Solutions Compound Solubility (g/100 m.

The Solubility of Barium and Silver Salts in Aqueous Solutions Compound Solubility (g/100 m. L) Temperature (°C) 0. 12 37. 5 67. 5 8. 7 0. 01 - 0. 02 2. 2 x 10 -4 182 2. 8 x 10 -7 8. 9 x 10 -5 0. 155 3. 7 x 10 -4 122 0. 57 25 26 20 20 N/A 25 15. 5 25 10 0 100 Ba. F 2 Ba. Cl 2 Ba(NO 2)2 Ba(NO 3)2 Ba. HPO 4 Ba 2 SO 4 Ag. F Ag. I Ag. Cl Ag. NO 2 Ag. Br Ag. NO 3 Ag 2 SO 4 a Grace company

Maxi-Clean™ IC-Ba Product Specifications Packing: Particle Size: Capacity: Retains: Applications: Strong cation exchanger in

Maxi-Clean™ IC-Ba Product Specifications Packing: Particle Size: Capacity: Retains: Applications: Strong cation exchanger in the Ba 2+ form 106µm 0. 8/2. 4 meq. Sulfate by precipitation Removal of sulfate before the analysis of other anions a Grace company

Maxi-Clean™ IC-Ba Removes Sulfate 5348 Anions in Battery Acid 1. 2. 3. 4. 5.

Maxi-Clean™ IC-Ba Removes Sulfate 5348 Anions in Battery Acid 1. 2. 3. 4. 5. 6. 7. Fluoride Chloride Nitrite Bromide Nitrate Phosphate Sulfate Column: Mobile Phase: Flow rate: Detector: Original Sample a Grace company After Cleanup with Maxi-Clean™ IC-BA Anion/R, 250 x 4. 1 mm 5 m. M p HBA, p. H 8. 5 1. 5 m. L/min. Alltech Conductivity

Average % Recovery of Ions with Maxi-Clean™ IC-Ba Cartridge a Grace company

Average % Recovery of Ions with Maxi-Clean™ IC-Ba Cartridge a Grace company

Maxi-Clean™ IC-Ag Product Specifications Packing: Particle Size: Capacity: Strong cation exchanger in Ag+ form

Maxi-Clean™ IC-Ag Product Specifications Packing: Particle Size: Capacity: Strong cation exchanger in Ag+ form Retains: Halides by precipitation Removal of halides before analysis of other anions Applications: 106µm 0. 8/2. 4 meq. a Grace company

Maxi-Clean™ IC-Ag Removes Chloride 5347 1 Nitrite in Brine 1. Chloride 2. Nitrite 2

Maxi-Clean™ IC-Ag Removes Chloride 5347 1 Nitrite in Brine 1. Chloride 2. Nitrite 2 Original Sample a Grace company After Cleanup with Maxi-Clean™ Column: 250 x 4. 1 mm Packing: Anion/R Mobile Phase: 5 m. M p HBA, p. H 8. 5 Flow rate: 1. 5 m. L/min. Detector: Alltech Conductivity

Average % Recovery of Ions with Maxi-Clean™ IC-Ag Cartridge a Grace company

Average % Recovery of Ions with Maxi-Clean™ IC-Ag Cartridge a Grace company

Maxi-Clean™ Cartridges to Adjust Sample p. H • Baseline disturbances and/or system peaks result

Maxi-Clean™ Cartridges to Adjust Sample p. H • Baseline disturbances and/or system peaks result when sample p. H differs from eluant p. H. • Strong anion exchange resin in the hydroxide form removes anions and neutralizes an acidic sample. • Cation exchange resin in the hydrogen form removes cations and neutralizes an alkaline sample. a Grace company

Maxi-Clean™ IC-OH Product Specifications Packing: Particle Size: Capacity: Retains: Applications: a Grace company Strong

Maxi-Clean™ IC-OH Product Specifications Packing: Particle Size: Capacity: Retains: Applications: a Grace company Strong anion exchanger in OH- form 75µm 0. 6/1. 8 meq Anions Adjusting sample p. H before cation analysis

Maxi-Clean™ IC-OH Neutralizes Acid 5352 Monovalent Cations in 1 M Nitric Acid 1. Sodium

Maxi-Clean™ IC-OH Neutralizes Acid 5352 Monovalent Cations in 1 M Nitric Acid 1. Sodium 2. Potassium Column: Cation/R, 100 x 43. 1 mm Mobile Phase: 3. 2 m. M nitric acid Flowrate: 1. 0 m. L/min Detector: Alltech Conductivity Original Sample a Grace company After p. H Neutralization with Maxi-Clean™ IC-OH

Recovery of Ions with Maxi-Clean™ IC-OH Cartridges a Grace company

Recovery of Ions with Maxi-Clean™ IC-OH Cartridges a Grace company

Maxi-Clean™ IC-H Product Specifications Packing: Particle Size: Capacity: Retains: Applications: a Grace company Strong

Maxi-Clean™ IC-H Product Specifications Packing: Particle Size: Capacity: Retains: Applications: a Grace company Strong cation exchanger in H+ form 106µm 0. 8/2. 4 meq. Cations Adjusting sample p. H before anion analysis

Maxi-Clean™ IC-H Neutralizes Hydroxide Trace Anions In Caustic Solution 1. 2. 3. 4. 5.

Maxi-Clean™ IC-H Neutralizes Hydroxide Trace Anions In Caustic Solution 1. 2. 3. 4. 5. 6. 7. 8. Original Sample After p. H Neutralization with Maxi-Clean™ IC-H a Grace company 5349 Fluoride Bicarbonate Chloride Nitrite Bromide Nitrate Phosphate Sulfate Column: Anion/R, 150 x 4. 1 mm Mobile Phase: 5 m. M p. HBA, p. H 8. 5 Flowrate: 1. 5 m. L/min. Detector: Alltech Conductivity

Recovery of Ions with Maxi-Clean™ IC-H Cartridges a Grace company

Recovery of Ions with Maxi-Clean™ IC-H Cartridges a Grace company

Maxi-Clean™ IC-Na Product Specifications Packing: Particle Size: Capacity: Retains: Applications: Strong cation exchanger in

Maxi-Clean™ IC-Na Product Specifications Packing: Particle Size: Capacity: Retains: Applications: Strong cation exchanger in Na+ form 106µm 0. 8/2. 4 meq. Cations (exchanges cations for sodium) Removal of cations from sample without changing sample p. H a Grace company

Maxi-Clean™ IC-Na+ Isolates Iron (III) 5813 Analysis of Iron (III) Procedures: 1. Precondition IC-Na+

Maxi-Clean™ IC-Na+ Isolates Iron (III) 5813 Analysis of Iron (III) Procedures: 1. Precondition IC-Na+ cartridge with 5 m. L water. 2. Load the sample to preconcentrate iron (III) present. 3. Wash with 10 m. L water. 4. Elute the iron (III) with 5 m. L of 25 m. M EDTA, disodium salt. 5. Analyze the eluant for iron (III). 1. Iron (III) Column: Alltech Universal Anion, 150 x 4. 6 mm Mobile Phase: 2 m. M EDTA, disodium salt Flowrate: 1. 0 m. L/min. Detector: UV at 330 nm *Problem with IC-H+--> the precipitation of H 4 EDTA a Grace company

Maxi-Clean™ IC-Chelate Product Specifications Packing: Particle Size: Capacity: Retains: Applications: a Grace company Styrene-divinylbenzene

Maxi-Clean™ IC-Chelate Product Specifications Packing: Particle Size: Capacity: Retains: Applications: a Grace company Styrene-divinylbenzene copolymer containing iminodiacetate ion 225µm 0. 2/0. 6 meq. Polyvalent metal ions (exchanges cations for sodium) Removal of polyvalent metal ions from sample

Benefits of Alltech Maxi-Clean™ IC Cartridges • Remove interfering components from the sample matrix.

Benefits of Alltech Maxi-Clean™ IC Cartridges • Remove interfering components from the sample matrix. • Little or no loss of sample. • Easy, quick, and convenient. • Disposable. a Grace company