ANL Section 1 ANL Features ANL ANL heat

  • Slides: 24
Download presentation
ANL

ANL

Section 1: ANL Features

Section 1: ANL Features

ANL • ANL heat pumps have been designed and constructed to satisfy small and

ANL • ANL heat pumps have been designed and constructed to satisfy small and medium sized cooling and heating applications in residential or commercial venues • Arranged for using hydraulic circuits (evaporator and condensing unit) therefore it can be used like water chiller and heat pump • The units can have with base or with integrated pump and storage tank • Ability to produce domestic hot water

ANL Description of Components Scroll Compressors • High efficiency scroll type hermetic compressors, assembled

ANL Description of Components Scroll Compressors • High efficiency scroll type hermetic compressors, assembled on elastic anti-vibration supports, driven by a 2 -pole electric motor with internal thermal protection of the electric heater casing included as standard Water Side Heat Exchanger • Of the plate type (AISI 316), external insulated with closed cell material to reduce thermal dispersion • Fitted, as standard, with antifreeze heater Source Side Heat Exchanger • Made with copper pipes and aluminum louved red fins blocked by mechanical expansion of the pipes

ANL Description of Components Dehydrator Filter • Able to withhold impurities and any traces

ANL Description of Components Dehydrator Filter • Able to withhold impurities and any traces of humidity present in the cooling circuit One Way Valves • Allows on way flow of the fluid Thermostatic Valve • The mechanical valve with external equalizer positioned at the evaporator inlet ensures correct heating level of the intake gas Solenoid Valve • The valve closes when the compressor turns off which prevents the flow of refrigerant gas towards the evaporator • s

ANL Description of Components Indicator For Liquid Passage with Humidity Presence Signal • Used

ANL Description of Components Indicator For Liquid Passage with Humidity Presence Signal • Used to check the refrigerant gas load and the eventual presence of humidity in the cooling circuit 4 -Way Reverse Valve • Inverts the flow of refrigerant gas One-Way Valves • Allows the passage of the refrigerant in just one direction Liquid Storage Tank • Compensate the difference in volume between louvers coil and plate exchanger, withholding excess liquid • s

ANL Features R 410 A From 94755 Btu/hr to 111850 Btu/hr Refrigerant Versions Available

ANL Features R 410 A From 94755 Btu/hr to 111850 Btu/hr Refrigerant Versions Available Heating Capacity Cooling Capacity ANL Standard ANL”H” Heat Pumps From 6. 57 Tons to 8. 16 Tons

ANL Features Axial fans for quiet operation Differential switch as standard supply Max water

ANL Features Axial fans for quiet operation Differential switch as standard supply Max water out is 122˚F Metallic protective cabinet with rustproof polyester paint High efficiency heat exchangers and scroll compressors Silenced Operation

ANL Power Supply: 460/3/60 Power Supply: 220/3/60

ANL Power Supply: 460/3/60 Power Supply: 220/3/60

ANL Operating Range Heating Mode Inlet water temperature: 104°F Outlet water temperature: 113°F Outside

ANL Operating Range Heating Mode Inlet water temperature: 104°F Outlet water temperature: 113°F Outside air temperature: 45/43°F Cooling Mode Inlet water temperature: 54°F Outlet water temperature: 45°F Outside air temperature: 95°F

Section 2: ANL Dimensions, Internal Layout and Technical Data

Section 2: ANL Dimensions, Internal Layout and Technical Data

ANL Dimensions 100 150

ANL Dimensions 100 150

ANL Dimensions A Height 57 inches C Width 30 inches B Length 69 inches

ANL Dimensions A Height 57 inches C Width 30 inches B Length 69 inches

ANL Internal Layout

ANL Internal Layout

ANL Technical Data

ANL Technical Data

ANL Electrical Data

ANL Electrical Data

ANL Main Cooling Layout

ANL Main Cooling Layout

Section 3: ANL Accessories

Section 3: ANL Accessories

ANL Accessories Accessory Explanation VT Anti-vibration mounts MODU-485 RS 485 interface for supervision systems

ANL Accessories Accessory Explanation VT Anti-vibration mounts MODU-485 RS 485 interface for supervision systems with MODBUS protocol AERWEB 300 Allows remote control of a chiller through a standard PC and Ethernet connection with a standard browser. The unit must be equipped with MODU-485 A DCPX Low temperature device for correct cooling mode operation with ambient temperatures from less than 68 °F down to 14°F Multicontrol Allows the simultaneous control of several chillers or heat pumps (up to 4) fitted with the Moducontroller and installed in the same hydraulic system

ANL Accessories Accessory Explanation PR 3 Simplified remote panel that permits control of basic

ANL Accessories Accessory Explanation PR 3 Simplified remote panel that permits control of basic unit functions such as on/off, changing the operating mode, diagnostics and alarm reset SPLW System water temperature sensor - In most cases the loose supplied sensors for each chiller/ heat pump are sufficient - In cases of a common flow/return header this sensor can be used to control the common system supply water temperature for the chillers connected to the header, or it can be used for temperature monitoring SDHW Domestic hot water temperature sensor that is used with the storage tank to control the temperature of water produced BDX Condensate drip tray with integrated electric heater controlled by external air temperature sensor

ANL Factory Fitted Accessories Accessory Explanation DRE Electronic soft starter device reducing starting current

ANL Factory Fitted Accessories Accessory Explanation DRE Electronic soft starter device reducing starting current by about 30% KR Anti-freeze electric heater for the plate heat exchanger (not available for sizes 020 AHA to 040 A-HA) KRB Electric anti-freeze heater for the base RA Anti-freeze electric heater for the buffer tank

ANL Multi-Control The Multi-Control accessory manages the units through an RS 485 serial connection

ANL Multi-Control The Multi-Control accessory manages the units through an RS 485 serial connection if the units are equipped with the MODU 485 A accessory

ANL Multi-Control The Multi-Control is able to manage up to 4 ANL units

ANL Multi-Control The Multi-Control is able to manage up to 4 ANL units

Thank You For Your Time