ALTAIR 4 X Multigas Detector Its whats inside

  • Slides: 29
Download presentation
ALTAIR® 4 X Multigas Detector It’s what’s inside that counts!

ALTAIR® 4 X Multigas Detector It’s what’s inside that counts!

Our Vision of Safety Built on Durability – Based on tough Altair 4 Multigas

Our Vision of Safety Built on Durability – Based on tough Altair 4 Multigas Detector Powered by Performance – New High Performance XCell™ Sensors

XCell Technology § Typical life >= 4 Years – 60% longer sensor life than

XCell Technology § Typical life >= 4 Years – 60% longer sensor life than the industry average – Standard 3 year warranty § XCell-erated response time, clear time, bump test – 38% faster response time than the industry average – Typical <= 15 seconds § Typical cost of ownership savings > 50% – Longer sensor life and fast response – 50% less calibration gas used per minute than industry average § Embedded microelectronics elevate performance – Each sensor has a microprocessor and digital output

Application Specific Integrated Circuit (ASIC) § Industry 1 st! Every XCell Sensor has an

Application Specific Integrated Circuit (ASIC) § Industry 1 st! Every XCell Sensor has an embedded ASIC! – Microprocessor, memory, and all circuitry to drive the sensor – Digital output § Way beyond a “Smart Sensor” – Competitor’s “Smart Sensors” have a passive memory chip to store gas type, serial number, initial sensor settings, etc…. – The MSA ASIC drives the sensor, actively compensates the output, and coverts it into a digital signal. § Benefit – Higher performing sensors with greater stability

XCell O 2 Sensor Life § Most Other O 2 Sensors (Typical Life <=

XCell O 2 Sensor Life § Most Other O 2 Sensors (Typical Life <= 2 years) – Use a consumable chemical reaction – Filled with lead which is converted to lead oxide – Sensor dies as lead is depleted (limited shelf life) § XCell O 2 Sensor (Typical Life >= 4 years) – Non-consuming chemical reaction (No lead) – O 2 reduced to water and then oxidized back to O 2 – Vastly increased shelf life

XCell Ex Sensor Life § Most Other LEL Sensors (Typical Life = 2 years)

XCell Ex Sensor Life § Most Other LEL Sensors (Typical Life = 2 years) – End of life caused by slow poisoning • Poisoned by silicon, sulphur, or lead containing compounds – End of life can also result from a large physical shock § XCell Ex Sensor (Typical Life = 4 years) – Two detectors double the active life of the sensor – Only one detector is catalytically active at a time – Metal alloy support rod added to increase durability

XCell CO/H 2 S Sensor Life § Most Other CO/H 2 S Sensors (Life

XCell CO/H 2 S Sensor Life § Most Other CO/H 2 S Sensors (Life = 2 -3 years) – Chemical poisoning of the electrode material – Loss of sensitivity due to electrolyte drying out § XCell CO/H 2 S Sensor (Typical Life >= 4 years) – Increased active sites on electrodes • Increase sensitivity • Reduce the effects of poisoning – Robust carbon filter to protect the CO electrode – Expansion electrolyte well minimizes drying effect

Response Times Significantly Faster Than the Competition! § Span Calibration: 60 sec § Bump

Response Times Significantly Faster Than the Competition! § Span Calibration: 60 sec § Bump Test: < 15 sec § Combustible sensor t 90 <10 seconds (Methane) t 90 <15 seconds (Pentane) § Oxygen sensor t 90 < 10 seconds § CO sensor t 90 < 15 seconds § H 2 S sensor t 90 < 15 seconds

XCell Sensor § Designed and built by MSA – MSA IS Advancing Sensor Technology!

XCell Sensor § Designed and built by MSA – MSA IS Advancing Sensor Technology! – Our sensors are designed for OUR instruments! – We have the experts to support YOU!

Altair 4 X Multigas Detector Personal 4 -gas monitor – Detects O 2, H

Altair 4 X Multigas Detector Personal 4 -gas monitor – Detects O 2, H 2 S, CO, combustible gas – Rechargeable lithium-polymer battery Standard: – Event log – Full data log – Vibrating alarm – Motion. Alert™ – Instant. Alert™

Small Size § Small, unobtrusive, lightweight design § § § Easy to wear all

Small Size § Small, unobtrusive, lightweight design § § § Easy to wear all day Alarms visible from 360º Fits in gloved hand One-handed operation Robust construction

Rugged Design § Over-molded case design § Built-in rubberized armor § Impact shock protection

Rugged Design § Over-molded case design § Built-in rubberized armor § Impact shock protection – Withstands 20 -foot drop § Easy to grasp and hold § Sealed against water/dust ingress to IP 67 – Third-party tested – Dunk it in a bucket!

Multiple Alarms § 95+ d. B horn typical § Multiple, alternating high-intensity alarm LEDs

Multiple Alarms § 95+ d. B horn typical § Multiple, alternating high-intensity alarm LEDs – On top and bottom of unit! § Vibrating alarm is standard on all models § Instant. Alert™ feature standard – Activates all alarms when desired § Motion. Alert™ feature standard – If no motion is detected for 30 seconds, alarm sounds to alert others – Ideal for confined space entry

Provides Confidence signal – Green blinking Safe LED – Vibrating pulse – Confidence beep

Provides Confidence signal – Green blinking Safe LED – Vibrating pulse – Confidence beep every 30 sec. to ensure operation Can be turned off – Setup mode

Advanced Features § MSA exclusive Motion. Alert™ feature – Indicates “man down” § MSA

Advanced Features § MSA exclusive Motion. Alert™ feature – Indicates “man down” § MSA exclusive Instant. Alert™ feature – Activates all alarms when desired § Most rugged instrument in its class – Withstands 20 -foot drop § Agency certified IP 67 rating – Water and dust tight § Bump checkmark √ (24 hrs) – Displays successful test result

Advanced Features § Safe LED – Helps to ensures instrument’s properation § Missing sensor

Advanced Features § Safe LED – Helps to ensures instrument’s properation § Missing sensor alarm – Helps to prevent errors after service § Password-protected setup mode – Controls unauthorized access § Event & data log – >500 events and >50 hours § MSA Link™ Software-ready – Multi-language PC software to access records & change settings

Battery § Lithium-polymer technology § Virtually no memory effects § Holds charge better §

Battery § Lithium-polymer technology § Virtually no memory effects § Holds charge better § Runs average of 24 hours – No need for multiple instruments during long shifts

Many Markets § Oil and gas § Chemical § Fire § Utilities § Agriculture

Many Markets § Oil and gas § Chemical § Fire § Utilities § Agriculture § Construction § Steel § Water § Various industrial applications

Start-up Operation similar to that of Altair 4 & Solaris® Multigas Detectors: §Performs diagnostic

Start-up Operation similar to that of Altair 4 & Solaris® Multigas Detectors: §Performs diagnostic self-check – Display – 3 alarms – Sensor discovery §Displays: – – – Instrument name Software version Combustible gas type Toxic units (ppm or mg/m 3) Alarm set points (Low, High, STEL, TWA)

Start Up § Displays expected calibration gas concentrations § Shows current time and date

Start Up § Displays expected calibration gas concentrations § Shows current time and date § Indicates last successful cal. date § Indicates next cal. date (if activated) § Shows measurement countdown § Offers fresh air setup option § Defaults to measurement page

Pages § § § § § Measurement (default) Bump Peak readings Minimum oxygen reading

Pages § § § § § Measurement (default) Bump Peak readings Minimum oxygen reading STEL for toxics (if activated) TWA for toxics (if activated) Time Date Motion. Alert™ feature

Data Log § Event logging (500 events) – – – Gas and battery alarms

Data Log § Event logging (500 events) – – – Gas and battery alarms Calibration & bump records Battery voltage FAS, re-zero, calibration Reset of TWA, STEL & Peak § Gas records(>50 hours) – – Reading Time and date Peak, Min, Average Temperature § Graphs & tables § Infrared-based MSA Link Software-compatible – Change instrument settings § Last successful calibration date

Setup § Password-protected access § Change: – – – – Individual sensor channels Combustible

Setup § Password-protected access § Change: – – – – Individual sensor channels Combustible gas type Auto calibration values Calibration due on/off Alarm set points Low, High, STEL, TWA Date Time § Other settings through MSA Link Software

Calibration § Single-button auto cal-based – Access can be password-protected § Same Altair 4

Calibration § Single-button auto cal-based – Access can be password-protected § Same Altair 4 & Solaris® Detector calibration cylinders – – 1. 45% CH 4 60 ppm CO 15% O 2 20 ppm H 2 S • 10048280 (34 L) • 10045035 (58 L)

Calibration 1. Press and hold ▲ button 2. Instrument prompts user to “Zero Cal?

Calibration 1. Press and hold ▲ button 2. Instrument prompts user to “Zero Cal? ” 3. Press to accept & initiate zero function – Or press ▲ to cancel function 4. Unit will automatically zero sensors – Zero pass 5. Instrument prompts user to “Span Cal? ” 6. Attach cal. cap & flow cal. gas to instrument 7. Press to accept & initiate span – Or press ▲ to cancel function 8. Unit automatically spans sensors

Accessories § Galaxy® Automated Test System – Bump test and calibration – Record keeping

Accessories § Galaxy® Automated Test System – Bump test and calibration – Record keeping § Quick. Check® Station – Bump test only – Records activities § Charging cradle § Multi-Unit Charger – Up to 10 instruments § Universal pump probe

Low Maintenance Low level of end-user maintenance required: § § § Separate sensors Sensor

Low Maintenance Low level of end-user maintenance required: § § § Separate sensors Sensor replacement kit Filter, gasket, etc. kit Front case with built-in filter Battery and electronics Most components available as replacement parts

Warranty Standard 3 -year warranty – Sensors – Electronics – Battery Optional extended warranty

Warranty Standard 3 -year warranty – Sensors – Electronics – Battery Optional extended warranty – 1 year extra = 4 years total – Part of ATO!

Questions? Thanks!