AFFF FIREFIGHTING SYSTEMS AFFF SYSTEMS n HIGH CAPACITY
- Slides: 24
AFFF FIREFIGHTING SYSTEMS
AFFF SYSTEMS n HIGH CAPACITY SYSTEMS
AFFF FACTS CLEAR TO SLIGHTLY AMBER APPEARANCE n INDEFINITE SHELF LIFE n STORE AT TEMPERATURES >320 F (if AFFF freezes, it may be used after thawing) n 94% WATER / 6% FOAM MIX n
AFFF FACTS MIXES WITH WATER TO FORM AN AQUEOUS FILM WHICH EXCLUDES OXYGEN FROM THE SURFACE OF THE FUEL n COOLS DUE TO WATER CONTENT n EXCELLENT PENETRATING CHARACTERISTICS / SUPERIOR TO WATER ON CLASS “A” FIRES n
AFFF FACTS n GENERAL PRECAUTIONS u AFFF IS EXTREMELY CORROSIVE u ENSURE SYSTEM IS PROPERLY ALIGNED FOLLOWING EACH USE u AVOID INADVERTENT CONTACT WITH ELECTRICAL EQUIPMENT u WHEN SYSTEM MAINTENANCE IS BEING PERFORMED ENSURE YOU ARE KEPT ABREAST OF FIRE FIGHTING CAPABILITY
AFFF FACTS n GENERAL PRECAUTIONS u SOME FORMATION/COLLECTION OF H 2 S MAY OCCUR IN PIPING/AREAS WHERE AFFF STANDS STAGNANT FOR A PERIOD OF TIME, PARTICULARLY IN THE BALANCED PROPORTIONING SYSTEM
AFFF SYSTEM COMMON ITEMS n OVERBOARD DISCHARGE REQUIREMENTS u <3 NM FROM LAND - NO OVERBOARD DISCHARGE u 3 - 12 NM FROM LAND - DISCHARGE PERMITTED IF SHIP SPEED IS 10 KTS OR HIGHER u >12 NM FROM LAND - DISCHARGE AS REQUIRED
AFFF SYSTEM COMMON ITEMS n DC DECK RE-ENTRY HOSE REELS u 125’ NON COLLAPSIBLE RUBBER HOSE WITH 11/2 INCH 95 GPM VARI NOZZLE (100’ ON MHC) u HOSE REEL CUTOUT VALVE NORMALLY CLOSED
AFFF SYSTEM COMMON ITEMS n ENGINEERING SPACE HOSE REELS u 50’ NON COLLAPSIBLE RUBBER HOSE WITH 11/2 INCH 95 GPM VARI NOZZLE u HOSE REEL CUTOUT VALVE LOCKED OPEN.
AFFF SYSTEM COMMON ITEMS n ENGINEERING SPACE HOSE REELS u 27 LB PORTABLE PKP CYLINDER LOCATED NEAR EACH AFFF HOSE REEL
AFFF SYSTEM COMMON ITEMS n SERVICE VALVE TEST CASTING u ALLOWS FOR TESTING OF BILGE SPRINKLING SYSTEM WITHOUT SPRINKLING THE BILGES n AFFF CONCENTRATE TANKS u MANUFACTURED FROM 9010 CUNI OR STAINLESS u VENT/VACUUM BREAKER. 05 PSIG/. 05”Hg
SERVICE VALVE TEST CAST FITTING BILGE SPRINKLING SERVICE VALVE TEST FITTING INLET CHAIN TEST CONNECTION CAP
FIXED EDUCTOR SYSTEM n HIGH POINTS u FOUND ON MHC / MCM u MCM F FORWARD TANK CAPACITY 50 GL F AFT TANK CAPACITY 200 GL u MHC F TANK CAPACITIES 75 GL FWD / AFT
FIXED EDUCTOR SYSTEM n n n TANKS ARE REFILLED VIA GRAVITY FROM STORAGE TANK LOCATED NEAR STACKS PMS CHECK FOR AFFF CONCENTRATE SEAWATER CONTAMINATION IS DONE QUARTERLY OVERHEAD SPRINKLERS INSTALLED IN MHC CLASS SHIPS
BPPS AFFF System FILL CONNECTION TO HOSE STATION OUTLETS LOW FLOW RATE AFFF CONCENTRATE TANK DEMAND USERS HIGH FLOW RATE DEMAND USERS GAUGE RECIRC CUTOUT M AFFF PUMP GAUGE F/M SOPV MASTER SOPV POWERCHECK VALVE HYCHECK VALVE SOPV
2 SPEED INJECTION SYSTEM n HIGH POINTS u PUMPS RATED AT 27/65 GPM @175 PSI F 27 GPM - LOW FLOW RATE DEMAND USER (HOSE LINE, ELEVATOR SRINKLER, etc) F 65 GPM - HIGH FLOW RATE DEMAND USER (HANGAR SPRINKLER, etc) F POSITIVE DISPLACEMENT ROTARY VANE TYPE PUMP F MOTOR CONTROLLER POWERED FROM ABT F START LOCAL/ REMOTE. MUST BE STOPPED LOCALLY
DECK EDGE NOZZLES FLUSH DECK NOZZLES PRESSURE SWITCHES Single Speed Injection AFFF System POWERTROL TYPE VALVE F/M SOPV O 3 LEVEL MAIN DECK TO TRANSFER SYSTEM PUMP DISCHARGE GAGE ALTITUDE GAGE HYDRAULIC CHECK VALVE 2 ND DECK 600 GALLON AFFF CONCENTRATE TANK AFFF CONCENTRATE PUMP
SINGLE SPEED AFFF SYSTEM n HIGH POINTS u SERVICES HANGAR AND FLIGHT DECK AREAS, PUMP ROOMS u FLUSH DECK NOZZLES u DECK EDGE NOZZLES u ELECTRIC PUSHBUTTON AT EACH HOSE OUTLET
HIGH CAPACITY AFFF SYSTEM n HIGH POINTS u TYPES INSTALLED IN NAVY SHIPS F BALANCED PRESSURE PROPORTIONER F ELECTRIC 2 SPEED AFFF PUMP SYSTEM F HIGH CAPACITY SINGLE SPEED PUMP
SUMMARY n FOAM GENERATING SYSTEMS u 2 SPEED INJECTION SYSTEM u HIGH CAPACITY SYSTEMS
REVIEW QUESTION n WHAT RULES APPLY WITH RESPECT TO THE DISCHARGE OF AFFF INTO THE SEA WHEN: u INPORT / 3 NM FROM LAND? u PROHIBITED u 3 -12 NM FROM LAND? u IF SHIP SPEED IS > 10 KTS u >12 NM FROM LAND? u DISCHARGE AT WILL
REVIEW QUESTION n n DESCRIBE THE ACTIVATION SEQUENCE IN A 2 SPEED INJECTION SYSTEM WHEN THE LOW FLOW RATE DEMAND CIRCUIT IS ENERGIZED. THE MASTER SOPV IS ENERGIZED, STARTING THE AFFF CONCENTRATE PUMP ON SLOW AND OPENING THE HYCHECK AND POWERCHECK VALVES AS WELL AS ENERGIZING THE SOPV FOR THE LOW FLOW RATE GROUP (MINUS HOSE REELS)
REVIEW QUESTION n n WHAT ARE SOME OF THE DIFFERENT TYPES OF HIGH CAPACITY AFFF STATIONS? BALANCED PRESSURE PROPORTIONER 2 SPEED INJECTION SYSTEM SINGLE SPEED INJECTION SYSTEM
INSTALLED FIREFIGHTING SYSTEMS
- Floro-protein köpük konsantresi formülü
- Special protective equipment used in firefighting except
- Tactical ventilation
- Hux bar firefighting
- Condensed q formula
- Broken stream nozzle
- Receo vs fire
- 18 watchout situations for wildland firefighters
- At a bulk transport incident firefighters must
- Chimney chains firefighting
- Production units have an optimal rate of output where:
- Mass storage devices are specialized high capacity
- High precision vs high recall
- High precision vs high recall
- Directive supportive leadership
- High expectations high support
- Low accuracy low precision
- High directive and high supportive behavior
- Investasi adalah
- Scheduling ahead from a point in time.
- Cheap high security fence
- Excellent choice for systems requiring high reliability
- Slc vs sdlc
- Decision support systems and intelligent systems
- Engineering elegant systems: theory of systems engineering