Adjust capacity according to actual load Control refrigerant

  • Slides: 16
Download presentation

Adjust capacity according to actual load. Control refrigerant flow

Adjust capacity according to actual load. Control refrigerant flow

l l l Precise Room Temperature Control Less Temperature Fluctuation ± 0. 5°C from

l l l Precise Room Temperature Control Less Temperature Fluctuation ± 0. 5°C from Set Temperature Precise Temperature Control Inverter Conventional

Compressor speed according to load Rotating l l Quick Ramp-up of Compressor Achieved set

Compressor speed according to load Rotating l l Quick Ramp-up of Compressor Achieved set temperature faster

Running current Conventional System: • High starting current • Frequent on/off cycle Inverter System:

Running current Conventional System: • High starting current • Frequent on/off cycle Inverter System: • Low starting current • Smooth operation Time Compressor motor current ramps up smoothly

Compressor Capacity Heating Most Frequently Used Area Cooling Inverter Compressor Capacity

Compressor Capacity Heating Most Frequently Used Area Cooling Inverter Compressor Capacity

R 410 A DC Inverter R 22 AC Inverter Difference DC Brushless Compressor Motor

R 410 A DC Inverter R 22 AC Inverter Difference DC Brushless Compressor Motor AC Induction Compressor Motor Higher Efficiency Condensing Unit Single - split Multi - split A 5 LCX 010/015/020/025 C(R) A 5 MSX 020/025/030 A(R) AMSV 025/035 B

9, 000 2. 64 Btu/h k. W Single - split Multi - split Cooling

9, 000 2. 64 Btu/h k. W Single - split Multi - split Cooling Only Heat Pump 12, 000 3. 52 18, 000 5. 28 R 410 A DC 21, 000 6. 15 R 410 A DC 28, 000 8. 21 36, 000 10. 5 R 22 AC

A 5 LCX 10/15/20/25 C(R) Rated Cooling Capacity (min – max) k. W Rated

A 5 LCX 10/15/20/25 C(R) Rated Cooling Capacity (min – max) k. W Rated heating capacity (min – max) k. W Energy Efficiency W/W EER COP A 5 WMX 10 GR A 5 LCX 10 CR 2. 79 ( 0. 81 – 3. 27 ) 3. 37 ( 0. 79 – 4. 59 ) 3. 38 3. 44 A 5 WMX 15 GR A 5 LCX 15 CR 3. 52 ( 0. 81 – 4. 43 ) 3. 81 ( 0. 79 – 4. 74 ) 3. 21 3. 23 A 5 WMX 20 GR A 5 LCX 20 CR 5. 28 ( 1. 47 – 5. 86 ) 5. 57 ( 1. 47 – 6. 16 ) 3. 24 3. 37 A 5 WMX 25 GR A 5 LCX 25 CR 6. 16 ( 1. 47 – 6. 74 ) 6. 45 ( 1. 47 – 7. 03 ) 3. 09 3. 22 Model (Single-split)

A 5 MSX 20/25/30 A(R) Rated cooling capacity (min – max) k. W Rated

A 5 MSX 20/25/30 A(R) Rated cooling capacity (min – max) k. W Rated heating capacity (min – max) k. W M 5 MSX 20 AR (System 1 to 2) 5. 57 ( 1. 32 – 6. 15 ) M 5 MSX 25 AR (System 1 to 3) M 5 MSX 30 AR (System 1 to 4) Model (Multi-split) Energy Efficiency W/W EER COP 6. 15 ( 1. 32 – 6. 74 ) 3. 71 3. 77 6. 45 ( 1. 32 – 7. 03 ) 7. 03 ( 1. 32 – 7. 62 ) 3. 20 3. 60 7. 62 ( 1. 32 – 8. 50 ) 8. 21 ( 1. 32 – 9. 38 ) 3. 20 3. 60

A 5 MSV 20/25 A Model (Multi-split) MSV 25 A Rated cooling capacity (min

A 5 MSV 20/25 A Model (Multi-split) MSV 25 A Rated cooling capacity (min – max) k. W Energy Efficiency W/W 2. 57 System ( 1 -to-4) 7. 32 (1. 76 – 8. 21) 2. 79 System ( 1 -to-4) 10. 5 (2. 34 – 11. 1) MSV 35 A

Ceiling Cassette A / C Series Wide Selection of Indoor Units Wall Mounted G

Ceiling Cassette A / C Series Wide Selection of Indoor Units Wall Mounted G Series Ceiling Concealed C Series Ceiling Convertible E Series

l Applied for AC and DC Inverters l Applied for single split and multi

l Applied for AC and DC Inverters l Applied for single split and multi split

Capability l Intercepts or captures communication signals within the inverter electronics nervous system.

Capability l Intercepts or captures communication signals within the inverter electronics nervous system.

Displays Operating Parameters l l l l Temperature Readings for ALL sensors Compressor Running

Displays Operating Parameters l l l l Temperature Readings for ALL sensors Compressor Running Frequency EXV Pulse & Status Operating Mode Indoor Fan Speed Data Logging Data Storage & Transmission Graphical Representation

QUICK & EFFECTIVE TROUBLE-SHOOTING TOOL PIN-POINTS SPECIFIC PROBLEMATIC AREA / COMPONENT HIGH MOBILITY FOR

QUICK & EFFECTIVE TROUBLE-SHOOTING TOOL PIN-POINTS SPECIFIC PROBLEMATIC AREA / COMPONENT HIGH MOBILITY FOR EASIER ON-SITE SERVICE. * With Notebook USEFUL FOR ANALYSIS & FURTHER STUDY ABILITY TO GENERATE SERVICE REPORTS