AC 650 beauty in simplicity the NEW 650
AC 650 beauty in simplicity. . . the NEW 650 series ac inverters Ratings from 0. 2 - 90 k. W EUROTHERM DRIVES
AC 650 … simple to install … simple to set-up … simple to operate • no programming languages to learn • easy to navigate menu • ready-to-go from the box EUROTHERM DRIVES
AC 650 small in size… … long on features • built-in EMC compliant filters (up to 7. 5 k. W, footprint >7. 5 k. W) • DIN rail or direct panel mounting (up to 7. 5 k. W) • pre-programmed applications EUROTHERM DRIVES
AC 650 3 new compact frames H 137 3 W 73 D (mm) 142 H W D (mm) 192 73 173 H 257 W 96 D (mm) 195 2 1 EUROTHERM DRIVES 1 2 3 230 V 1 ph. 2 k. W. 37 k. W. 55 k. W. 75 k. W 230 V 1 ph 1. 1 k. W 1. 5 k. W 400 V 3 ph. 37 k. W. 55 k. W. 75 k. W 1. 1 k. W 1. 5 k. W 2. 2 k. W 400 V 3 ph 3. 0 k. W 4. 0 k. W 5. 5 k. W 7. 5 k. W
AC 650 All New Bookshelf Frames 2 230 V 1. 1 -1. 5 KW 380 -460 V. 37 -2. 2 KW 380 -460 V 3. 0 -7. 5 KW above … 7. 5 k. W 3 1 230 V. 25 -. 75 KW C D 11(15) KW 15(18. 5)-22(30) KW 380 -460 V …up to 7. 5 k. W EUROTHERM DRIVES E F 30(37)-45(55) KW 55(75)-90(110) KW (Ratings In Brackets) = Quadratic “Fan” Torque
AC 650 flexible inputs & outputs ONE option provides two features - Remote-mount keypad together with P 3 comms port POWER motor thermistor CONTROL volt-free relay contacts digital I/O • 8 presets AC line input • 2 programmable I/O motor analogue I/O • 0 - 10 V or 4 -20 m. A input • 1 programmable output for load or speed EUROTHERM DRIVES
simple operator controls AC 650 Backlit LCD display Speed, Hz, or units Rotation local /remote START STOP Locally mounted & removable or Remote-mount option raise / lower speed EUROTHERM DRIVES program menu
AC 650 VT (Variable Torque) fans & blowers centrifugal pumps EUROTHERM DRIVES simple & easy . . . for all your applications CT (Constant Torque) material conveyors batch mixers
AC 650 simple tuning for your load type Selectable v/f curves match your load requirement VT Vbase V CONSTANT TORQUE CT VARIABLE TORQUE f EUROTHERM DRIVES fbase
AC 650 simple programming Directions on cover back Application selection parameter! • Menu navigation • Set-up parameters • Diagnostics • Fault codes EUROTHERM DRIVES
AC 650 basic speed control 01 simple application programming Applications automatic/ manual 02 APPLICATION (1 -5) Max speed Min Speed Accel time Decel time Motor rated current Base frequency Jog setpoint Stop mode V/F shape HVAC ratings Fixed boost, (VF only) Password preset speeds 03 raise/ lower 04 Application 3, preset speeds p 301 Preset 0 : : p 308 Preset 7 STANDARD PARAMETERS p 1 p 2 p 3 p 4 p 5 p 6 p 7 p 8 p 9 p 11 p 12 p 13 p 99 p 1 Application 2, automatic/manual - STANDARD PARAMETER LIST with auto / manual control input selection EUROTHERM DRIVES PI control 05 Application 5, PI p 501 P gain p 502 I gain Application 4, raise/lower p 401 Ramp time p 402 Max value p 403 Min value p 404 Reset value
AC 650 DIAG Diagnostics d 1 d 2 d 3 d 4 Frequency (Hz) Speed setpoint (%) DC Link volts(v) Motor current (A) menu structure PAR Parameters STANDARD PARAMETERS p 1 APPLICATION (1 -5) (p 1=1) p 2 p 3 p 4 p 5 p 6 p 7 p 8 p 9 p 11 p 12 p 13 p 99 Max speed Min Speed Accel time Decel time Motor rated current Base frequency Jog setpoint Stop mode V/F shape HVAC ratings Fixed boost, (VF only) Password APPLICATION PARAMETERS p 1 = 2 Application 2, automatic/manual - STANDARD PARAMETER LIST - APPLICATION p 1 = 3 PARAMETERS appear only when selected p 1 = 4 p 1 = 5 Application 3, presets p 301 Preset 0 : : p 308 Preset 7 Application 4, raise/lower p 401 Ramp time p 402 Max value p 403 Min value p 404 Reset value Application 5, PI p 501 P gain p 502 I gain EUROTHERM DRIVES SET Setup IN Inputs IP 01 IP 02 IP 03 IP 04 IP 11 IP 12 IP 13 IP 21 IP 22 IP 23 Digin 1 invert Digin 2 invert Digin 3 invert Digin 4 invert Anin 1 scale Anin 1 offset Anin 1 type Anin 2 scale Anin 2 offset Anin 2 type TRIP Disabled Trips LOOPAnin 2 input break T 3 Anin 2 overload STLL Stall OT Motor over temp DB R Brake resistor DB S Brake switch OP Op station SET Setup ST 01 Jog accel time OUT Outputs OP 01 OP 02 OP 03 OP 04 OP 11 OP 12 OP 21 OP 22 OP 31 OP 32 Anout select Anout scale Anout offset Anout abs Digout 1 select Digout 1 invert Digout 2 select Digout 2 invert Relay select Relay invert SERLSerial Comms SE 01 Remote comms sel SE 02 Comms timeout SE 03 Address SE 04 Modbus baud rate SE 05 Modbus parity ST 02 Jog decel time ST 03 Ramp type ST 04 S-ramp jerk ST 05 S-ramp continuous ST 11 Skip frequency 1 ST 12 Skip freq band 1 ST 13 Skip frequency 2 ST 14 Skip freq band 2 ST 21 Auto restart attempts ST 22 Auto restart delay ST 23 Auto restart triggers ST 24 Auto restart triggers+ ST 31 Dynamic brake enable ST 32 DB resistance ST 33 DB power ST 34 DB over-rating
Application 1 : Basic Speed Control P 1 APPLICATION DIAGNOSTICS APPLICATIONS, CONSTANT TORQUE d 1 d 2 d 3 d 4 AND VARIABLE TORQUE 0 V Ref. AIN 1 AIN 2 +10 V REF AOUT 1 +24 V DIN 1 START FWD/REV DIN 2 DIGIO 1 JOG DIGIO 2 STOP 1 2 3 4 5 6 7 8 9 10 RL 1 A RL 1 B P 4 ACCEL TIME REFERENCE SELECT IP 23 AIN 2 TYPE 0 1 2 3 0 -10 V 0 -5 V 0 -20 m. A 4 -20 m. A P 5 DECEL TIME SEQUENCING LOGIC V/F SHAPING I FDBK CURRENT LIMIT V 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED R OP 31 RELAY EUROTHERM DRIVES SPEED DEMAND P 3 MIN SPEED NONE DEMAND% CURRENT% PID ERROR% RAISE/LOWER% P 9 STOP MODE RAMP FWD/REV P 8 JOG SPD OP 01 ANOUT 0 1 2 3 4 Application Max speed Min Speed Accel time Decel time Motor rated current Base frequency Jog setpoint Stop mode V/F shape HVAC ratings Fixed boost, (VF only) Password MIN/MAX SPEED 0 0 -10 V 1 0 -5 V OP 21 DIGIO 2 User Relay Frequency Hz Speed Setpt % DC Link Volts V Motor I A P 2 MAX SPEED IP 13 AIN 1 TYPE p 1 p 2 p 3 p 4 p 5 p 6 p 7 p 8 p 9 p 11 p 12 p 13 p 99 =1 IDEAL FOR GENERAL PURPOSE Feedback 4 -20 m. A STANDARD PARAMETERS 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED V V CT PWM CONTROL VT F P 13 V BOOST F F P 6 I NOMINAL P 7 BASE FREQ 60 Hz base frequency P 11 V/F SHAPE 0 = CONSTANT TORQUE 1 = VARIABLE TORQUE *BLUE is DEFAULT
Application 2 : Auto / Manual Control P 1 APPLICATION STANDARD PARAMETERS p 1 p 2 p 3 p 4 p 5 p 6 p 7 p 8 p 9 p 11 p 12 p 13 p 99 =2 IDEAL FOR AUTOMATIC DIAGNOSTICS CONTROL APPLICATIONS d 1 d 2 d 3 d 4 WITH LIMIT SWITCHES OR PROXIMITY TRANSDUCERS Frequency Hz Speed Setpt % DC Link Volts V Motor I A P 2 MAX SPEED AUTO REF 0 V MAN. AIN 1 REF AIN 2 +10 V REF AOUT 1 +24 V MAN. RUN AUTO RUN MAN. /AUTO DIN 1 DIN 2 DIGIO 1 DIGIO 2 FWD / REV IP 13 AIN 1 TYPE 1 2 3 4 5 6 7 8 9 10 MIN/MAX SPEED RL 1 A RL 1 B RAMP FWD/REV IP 23 AIN 2 TYPE 0 -10 V 0 -5 V 0 -20 m. A 4 -20 m. A SPEED DEMAND P 3 MIN SPEED P 5 DECEL TIME P 9 STOP MODE SEQUENCING LOGIC V/F SHAPING I FDBK CURRENT LIMIT V RUN SELECT 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED OP 21 DIGIO 2 User Relay P 4 ACCEL TIME REF SELECT 0 0 -10 V 1 0 -5 V 0 1 2 3 Application Max speed Min Speed Accel time Decel time Motor rated current Base frequency Jog setpoint Stop mode V/F shape HVAC ratings Fixed boost, (VF only) Password R OP 31 RELAY EUROTHERM DRIVES 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED V V CT PWM CONTROL VT F P 13 V BOOST F F P 6 I RATED P 7 BASE FREQ 60 Hz base frequency P 11 V/F SHAPE 0 = CONSTANT TORQUE 1 = VARIABLE TORQUE *BLUE is DEFAULT
Application 3 : Preset Speeds STANDARD PARAMETERS P 1 APPLICATION p 1 p 2 p 3 p 4 p 5 p 6 p 7 p 8 p 9 p 11 p 12 p 13 p 99 =3 IDEAL FOR APPLICATIONS DIAGNOSTICS WHERE MULTIPLE d 1 d 2 d 3 d 4 DISCRETE SPEED LEVELS (SCALABLE) ARE REQUIRED IP 300 PRESET 0 Frequency Hz Speed Setpt % DC Link Volts V Motor I A IP 301 PRESET 1 AUTO REF P 2 MAX SPEED IP 302 PRESET 2 IP 303 PRESET 3 0 V MAN. AIN 1 REF AIN 2 +10 V REF AOUT 1 +24 V START/STOP PRESET IN DIN 1 DIN 2 DIGIO 1 DIGIO 2 1 2 3 4 5 6 7 8 9 10 RL 1 A RL 1 B P 4 ACCEL TIME MIN/MAX SPEED IP 304 PRESET 4 RAMP FWD/REV SPEED DEMAND IP 305 PRESET 5 IP 306 PRESET 6 IP 307 PRESET 7 P 3 MIN SPEED P 5 DECEL TIME DIGIO 2 DIGIO 1 DIN 2 PRESET 0 V 0 V 24 V 1 0 V 0 V 24 V 2 3 24 V 0 V 0 V 4 24 V 24 V 0 V 5 6 24 V 24 V 7 SEQUENCING LOGIC P 9 STOP MODE User Relay Application Max speed Min Speed Accel time Decel time Motor rated current Base frequency Jog setpoint Stop mode V/F shape HVAC ratings Fixed boost, (VF only) Password R OP 31 RELAY EUROTHERM DRIVES 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED V/F SHAPING I FDBK CURRENT LIMIT V V V CT PWM CONTROL VT F P 13 V BOOST F F P 6 I NOMINAL P 7 BASE FREQ 60 Hz base frequency P 11 V/F SHAPE 0 = CONSTANT TORQUE 1 = VARIABLE TORQUE *BLUE is DEFAULT
Application 4 : Raise/Lower STANDARD PARAMETERS P 1 APPLICATION =4 IDEAL FOR APPLICATIONS DIAGNOSTICS WHICH REQUIRE SPEED d 1 d 2 d 3 d 4 CONTROL FROM MULTIPLE LOCATIONS Frequency Hz Speed Setpt % DC Link Volts V Motor I A P 2 MAX SPEED 0 V AIN 1 AIN 2 +10 V REF AOUT 1 +24 V START/STOP DIN 1 DIN 2 RAISE DIGIO 1 LOWER DIGIO 2 RESET RL 1 A RL 1 B RAMP FWD/REV P 3 MIN SPEED DEMAND P 5 DECEL TIME SEQUENCING LOGIC P 401 RAMP TIME P 402 MAX VALUE P 403 MIN VALUE V/F SHAPING R OP 31 RELAY EUROTHERM DRIVES CURRENT LIMIT CT PWM CONTROL V V VT F P 13 V BOOST 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED I FDBK V P 404 RESET VALUE P 9 STOP MODE User Relay Application Max speed Min Speed Accel time Decel time Motor rated current Base frequency Jog setpoint Stop mode V/F shape HVAC ratings Fixed boost, (VF only) Password P 4 ACCEL TIME MIN/MAX SPEED RAISE / LOWER 1 2 3 4 5 6 7 8 9 10 p 1 p 2 p 3 p 4 p 5 p 6 p 7 p 8 p 9 p 11 p 12 p 13 p 99 F F P 6 I NOMINAL P 7 BASE FREQ 60 Hz base frequency P 11 V/F SHAPE 0 = CONSTANT TORQUE 1 = VARIABLE TORQUE *BLUE is DEFAULT
Application 5 : PID Control STANDARD PARAMETERS P 1 APPLICATION =5 EASY TUNING FOR SETPOINT/ FEEDBACK CONTROL APPLICATIONS, REGULATING VOLUME OR PRESSURE, SUCH AS AIR HANDLING OR PUMPING P 501 P GAIN P 502 I GAIN 0 V Ref. AIN 1 AIN 2 +10 V REF AOUT 1 +24 V DIN 1 START FWD/REV DIN 2 DIGIO 1 JOG DIGIO 2 STOP PID CONTROL 1 2 3 4 5 6 7 8 9 10 RL 1 A RL 1 B d 1 d 2 d 3 d 4 Frequency Hz Speed Setpt % DC Link Volts V Motor I A Application Max speed Min Speed Accel time Decel time Motor rated current Base frequency Jog setpoint Stop mode V/F shape HVAC ratings Fixed boost, (VF only) Password P 4 ACCEL TIME MIN/MAX SPEED REFERENCE SELECT RAMP FWD/REV SPEED DEMAND P 8 JOG SPD P 3 MIN SPEED P 5 DECEL TIME OP 01 ANOUT 0 1 2 3 4 NONE SEQUENCING DEMAND% LOGIC CURRENT% PID ERROR% RAISE/LOWER% V/F SHAPING I FDBK CURRENT LIMIT V CT VT F R OP 31 RELAY EUROTHERM DRIVES 0 NONE 1 HEALTH 2 TRIPPED 3 RUNNING 4 AT ZERO 5 AT SPEED PWM CONTROL V V P 9 STOP MODE User Relay DIAGNOSTICS P 2 MAX SPEED Feedback 4 -20 m. A p 1 p 2 p 3 p 4 p 5 p 6 p 7 p 8 p 9 p 11 p 12 p 13 p 99 P 13 V BOOST F F P 6 I NOMINAL P 7 BASE FREQ 60 Hz base frequency P 11 V/F SHAPE 0 = CONSTANT TORQUE 1 = VARIABLE TORQUE *BLUE is DEFAULT
mount more drives per cabinet! AC 650 DIN rail VENTILATION mount on No side ventilation allows for zero clearance between drives! EUROTHERM DRIVES frames 1 -3
AC 650 the NEW 650 series ac inverters simple… smart… easy… EUROTHERM DRIVES
AC 650 the NEW 650 series ac inverters Thank you for your attention. Any Questions ? EUROTHERM DRIVES