ABB ibus EIB Display and Control Tableau Display
ABB i-bus® EIB Display and Control Tableau
Display and Control Tableau n n n © ABB STOTZ-KONTAKT Gmb. H - 2 C DC 510 030 N 0201, page 2 n n MT 701. 2 Display: 240 x 128 pixels 4 functional push buttons 2 cursor push buttons 1 push button for display illumination Illumination contrast via cursor push buttons Colours: white and silver Accessories: Wall box and cover frame
© ABB STOTZ-KONTAKT Gmb. H - 2 C DC 510 030 N 0201, page 3 Display and Control Tableau MT 701. 2 Programming n The MT 701. 2 is programmed with a ETS 2 -Plug-In n Actual state is displayed in the preview window n Push buttons in the preview window can be used for cursor actions or page changes n Download via RS 232 n Smaller changes can be downloaded via EIB n Helpfile and context oriented programming information
Display and Control Tableau MT 701. 2 Free programmable display pages Display element „Text“ Cursor Display element „Status“ Header n Living room © ABB STOTZ-KONTAKT Gmb. H - 2 C DC 510 030 N 0201, page 4 Ceiling light Wall light Shutter Scene Read Actual temperature Desired temperature On Push button 1 n Off 50% Scene Eat Push button 2 Scene TV 21. 2 °C 20. 5 °C Off Main menu Push button 3 n Push button 4 n n n 50 free programmable display pages 16 display elements Individual positioning of display elements Background picture Simple visualisation Free programmable page changes
Display and Control Tableau MT 701. 2 © ABB STOTZ-KONTAKT Gmb. H - 2 C DC 510 030 N 0201, page 5 Light scenes n 24 light scenes with 32 group addresses altogether (1 bit and 8 bit) n All light scenes can be called via EIB n Texts and values can be changed on the MT 701. 2 Time Switch n 16 channels n 8 switching times per channel n Switching and value telegrams can be send
Display and Control Tableau Alarm pages A L A R M n 12. 10. 2003 15: 06 Door is opened! n The balcony door in the living room is opened! n 1 act. window © ABB STOTZ-KONTAKT Gmb. H - 2 C DC 510 030 N 0201, page 6 Receipt MT 701. 2 back n n Up to 50 alarm pages Acoustical warning signal Receipt can be sent via EIB Alarm can also be triggered by internal telegramms (e. g. results of logical operations) Alarm list with last 100 alarm events (optional: Coming alarm, going alarm and receipt)
© ABB STOTZ-KONTAKT Gmb. H - 2 C DC 510 030 N 0201, page 7 Display and Control Tableau System page n Adjustment of date and time (can also be sent or received via EIB) n Change passwords n Alarm list n Adjustment of illumination contrast MT 701. 2
© ABB STOTZ-KONTAKT Gmb. H - 2 C DC 510 030 N 0201, page 8 Display and Control Tableau MT 701. 2 Values and thresholds n Value can be displayed (all EIS types) n Values can be sent via EIB n Surveil of upper and lower threshold n Threshold hysteresis and delay time adjustable n Threshold alarm can be displayed on the MT 701. 2 or sent via EIB n Up to 32 values can be surveilled for thresholds
© ABB STOTZ-KONTAKT Gmb. H - 2 C DC 510 030 N 0201, page 9 Display and Control Tableau MT 701. 2 Logical functions n Up to 80 logical operations - AND, OR, EX. OR - up to 8 inputs, 1 output - inputs and outputs can be inverted - an output can be connected to an input of another or the same logical operator n Up to 40 time elements - only 1 bit values - Switching on/off delay - Block via a blocking communication object - Filter telegrams n Up to 12 Multiplexer (1 to 2 / 1 to 4)
© ABB STOTZ-KONTAKT Gmb. H - 2 C DC 510 030 N 0201, page 10