A Vibrating Wire System For Quadrupole Fiducialization Zack
A Vibrating Wire System For Quadrupole Fiducialization Zack Wolf, Dave Jensen, Ralph Colon with help from Alexander Temnykh (Cornell) October 20, 2005 Quadrupole Fiducialization Procedure Zack Wolf 1 wolf@slac. stanford. edu
System Accuracy Requirements Total fiducialization error budget: 25 um Vertical and horizontal errors: Place wire at quadrupole center: 10 um Locate wire relative to tooling balls: 15 um Locate tooling balls on wire detector relative to tooling balls on magnet: 10 um LCLS PRD 1. 4 -001 October 20, 2005 Quadrupole Fiducialization Procedure Zack Wolf 2 wolf@slac. stanford. edu
System Overview LCLS-TN-05 -11 October 20, 2005 Quadrupole Fiducialization Procedure Zack Wolf 3 wolf@slac. stanford. edu
Place Wire At Quadrupole Center Similar To Pulsed Wire Technique October 20, 2005 Quadrupole Fiducialization Procedure Zack Wolf 4 wolf@slac. stanford. edu
System Under Construction October 20, 2005 Quadrupole Fiducialization Procedure Zack Wolf 5 wolf@slac. stanford. edu
Signals October 20, 2005 Quadrupole Fiducialization Procedure Zack Wolf 6 wolf@slac. stanford. edu
Set Resonant Frequency LCLS-TN-05 -11 In phase signal 90 degree out of phase signal October 20, 2005 Quadrupole Fiducialization Procedure Zack Wolf 7 wolf@slac. stanford. edu
Signal vs Magnet Position Measurements October 20, 2005 Quadrupole Fiducialization Procedure Zack Wolf 8 wolf@slac. stanford. edu
Wire Location LCLS-TN-05 -11 October 20, 2005 Quadrupole Fiducialization Procedure Zack Wolf 9 wolf@slac. stanford. edu
Wire Position Detector October 20, 2005 Quadrupole Fiducialization Procedure Zack Wolf 10 wolf@slac. stanford. edu
Conclusion A system is being constructed in which: 1) A quadrupole will be centered on a wire to 10 microns 2) The wire will be located relative to tooling balls to 15 microns 3) All tooling balls will be located to 10 microns The overall fiducialization accuracy in x and y will be better than 25 microns. The magnet pitch and yaw will be smaller than 1 mrad. More tests need to be done: repeatability, no bias, etc. October 20, 2005 Quadrupole Fiducialization Procedure Zack Wolf 11 wolf@slac. stanford. edu