2014 A Skills Mine Rescue Problem Mine Rescue
2014 A Skills Mine Rescue Problem
Mine Rescue Statement 2014 A • Welcome to the Happy Go Lucky Mine. This is a high wall mine with a history of water and bad roof conditions. This mine has one unit operating. We have a day shift and a second shift which rotates every two weeks. Midnight shift is a maintenance shift. This mine generates its power from a diesel generator, which breaks down two or three times a week. The generator has been broke down, but it is running at the present time. I received a call from the mechanic on the unit. He stated that there was a problem on the unit , and then we lost communication. We have had no further contact from the unit. There is power to the fresh air base. All power in by the fresh air base is off The fan is a blowing fan, and is on another power source. The fan is running, but may be turned off and on as needed. The fan has been examined and is being monitored. The map is up to date. We do not know how many people are underground. The tag board fell off the wall and all the tags are on the floor. That is all the information I have at this time.
Mine Rescue Problem • 2014 Skills Problem Make the mine in its entirety, where safe to do so. Account for all missing person, and bring all life persons to the Fresh air base,
Field Map Face 8 timbers X X Roof Bolter 5% CH 4 4 PPM CO 12. 9% O 2 BC B X One block knocked out BC X Battery Scoop X Borehole X person Purge Valve X D RA D D closed BC 5% CH 4 3 PPM CO 19. 1% O 2 Unsafe Roof XXXXXX caved Ankle deep water Water roofed pump switch off LC Door Open 5. 0% CH 4 6 PPM CO 19. 2% O 2 X permissible pump BO X 150’ of power cable X and discharge line . 5% CH 4 2 PPM CO 18. 5% O 2 X Harden room Airtight with door shut Fan switch on BC BC Blowing fan
Briefing officer Map pump switch off Door Open X permissible pump BO X 150’ of power cable X and discharge line X Harden room Airtight with door shut Fan switch on BC BC Blowing fan
Team Map pump switch off Door Open X permissible pump BO X 150’ of power cable X and discharge line X Harden room Airtight with door shut Fan switch on BC BC Blowing fan
Patient Statement RA Help get me out
Patient Statement Barricade in #2 Help get me out
Patient Statement Barricade in #3 Help get me out
2014 SIC Skills Handout Map Face X Roof Bolter B BC BC X Battery Scoop X Borehole X person Purge valve X D RA D D closed BC Unsafe Roof XXXXXX caved Ankle deep water Water roofed pump switch off LC Door Open X permissible pump BO X 150’ of power cable X and discharge line X Harden room Airtight with door shut Fan switch on BC BC Blowing fan
First Vent Face 8 timbers X X Roof Bolter 5% CH 4 4 PPM CO 12. 9% O 2 BC B X One block knocked out BC X Battery Scoop X Borehole X person D RA D closed BC CH 4 5% 3 PPM CO 19. 1% O 2 Unsafe Roof XXXXXX caved Ankle deep water Water roofed pump switch off . 5% CH 4 2 PPM CO 18. 5%O 2 LC Door Open 5. 0% CH 4 6 PPM CO 19. 2% O 2 X permissible pump BO X 150’ of power cable X and discharge line X Harden room Airtight with door shut Fan switch on BC BC If they pump # 2 and explore, there Is enough building material to isolate number 2 entry to wing # 1 Blowing fan
Team stop Map Once the timbers are found, you 8 timbers X Retreat to the person in # 1 Face X Roof Bolter Face 5% CH 4 4 PPM CO 12. 9% O 2 B X One block knocked out 5 If you found the gas outby in #3 entry you will have follow your containment in 3 # entry 8 6 BC BC X Battery Scoop X Borehole X person LC 9 D RA D closed 7 4 BC 5% CH 4 3 PPM CO 19. 1% O 2 Water roofed Pump water Ankle deep water Water roofed Unsafe Roof XXXXXX caved Pump water pump switch off Water roofed 1, 2 or 3 5% CH 4 6 PPM CO 19. 2% O 2 1, 2 or 3 Door Open X permissible pump BO X 150’ of power cable X and discharge line . 5% CH 4 2 PPM CO 18. 5% O 2 X Harden room Airtight with door shut Fan switch on BC BC Blowing fan
Second Vent Face 8 timbers X X Roof Bolter 5% CH 4 4 PPM CO 12. 9% O 2 6 B 3 X One block knocked out 4 BC BC X Battery Scoop X Borehole X person open D RA D closed 5 7 BC 5% CH 4 3 PPM CO 19. 1% O 2 8 Unsafe Roof XXXXXX caved Ankle deep water Water roofed pump switch off Water roofed 1 or 2 5. 0% CH 4 6 PPM CO 19. 2% O 2 Water roofed BO X 150’ of power cable X and discharge line BC BC . 5% CH 4 2 PPM CO 18. 5% O 2 1 or 2 LC Door Open X permissible pump This build is needed If you have pumped The water in # 3 X Harden room Airtight with door shut Fan switch on At the end of The problem props must be set in the Unsafe in #3 People may still be missing Blowing fan
Judges Map Face 8 timbers X X Roof Bolter 5% CH 4 4 PPM CO 12. 9% O 2 BC B X One block knocked out BC X Battery Scoop X Borehole X person D RA D closed BC 5% CH 4 3 PPM CO 19. 1% O 2 Unsafe Roof XXXXXX caved Ankle deep water Water roofed pump switch off Water roofed LC Door Open 5. 0%CH 4 6 PPM CO 19. 2% O 2 X permissible pump BO X 150’ of power cable X and discharge line . 5% CH 4 2 PPM CO 18. 5% O 2 X Harden room Airtight with door shut Fan switch on BC BC Blowing fan
Briefing officer Map pump switch off Door Open X permissible pump BO X 150’ of power cable X and discharge line X Harden room Airtight with door shut Fan switch on BC BC Blowing fan
- Slides: 15