2010. 12. 28 Switching Mode Power Supplies (SMPS) Power Supply Cook. Book (2 nd) – Marty Brown 윤자웅 Bio. Medical Instrumentation Lab. , BME, Yonsei
Contents 1. Introduction of PWM SMPS 2. The Fundamentals of PWM SMPS 3. The Building – Block Approach 4. Topologies of SMPS 5. “Black-Box”test Method Bio. Medical Instrumentation Lab. , BME, Yonsei
Intro. SMPS l Pulse Width Modulated (PWM) Power Supplies have been around for a long time. l However, it used from mid-1970 s broadly. l Advantages : i) Smaller in Size ii) More Efficient l Disadvantages : i) More difficult to Design ii) Radiate more Electromagnetic Interference (EMI) Bio. Medical Instrumentation Lab. , BME, Yonsei
The Fundamentals. l Saturation & Cutoff in Power TRs. : i) Low-V / High-I ii) High-V / Low-I ㅣ l “Chopping”&“Duty Ratio” l Two Major Type of SMPS 1) Forward-Mode Convertor 2) Boost-Mode Convertor Bio. Medical Instrumentation Lab. , BME, Yonsei
The Building – Block Approach - Design Flow First, Produce a very good “Paper Design” If you have a good library book or Data Sheet, it will be done within 8 Working hours. Bio. Medical Instrumentation Lab. , BME, Yonsei
The Building – Block Approach - Functional Block Diagram Bio. Medical Instrumentation Lab. , BME, Yonsei
Which Topology? § What is the Topology? § A Major decision is Which basic Topology to Use! § Each Topology has its relative merit. § The best choice provides the best performance at the needed cost Bio. Medical Instrumentation Lab. , BME, Yonsei
Which Topology? - Comparison of PWM SMPS Topologies 500 Bio. Medical Instrumentation Lab. , BME, Yonsei
Topologies § Buck Converter § Boost Converter § Buck-Boost Converter § Fly-Back Converter § 1 T Forward Converter § Push – Pull Converter § Half Bridge Converter § Full Bridge Converter Bio. Medical Instrumentation Lab. , BME, Yonsei
Topologies - Buck (Step Down) Converter Buck : 날뛰다 , 걷 잡을수 없다 Bio. Medical Instrumentation Lab. , BME, Yonsei
Topologies - Boost (Step up) Converter Bio. Medical Instrumentation Lab. , BME, Yonsei
Topologies : Buck-Boost Converter Bio. Medical Instrumentation Lab. , BME, Yonsei
Topologies : Fly-Back Converter Bio. Medical Instrumentation Lab. , BME, Yonsei
Topologies : 1 T – Forward Converter Bio. Medical Instrumentation Lab. , BME, Yonsei
Topologies : Push-Pull Converter Bio. Medical Instrumentation Lab. , BME, Yonsei
Topologies : Half-Bridge Converter Bio. Medical Instrumentation Lab. , BME, Yonsei
Topologies : Full-Bridge Converter Bio. Medical Instrumentation Lab. , BME, Yonsei
The “Black-Box”Considerations § What is the “Black-Block”test ? § This allows the designer to determine whether the choice of topology is correct Bio. Medical Instrumentation Lab. , BME, Yonsei
The “Black-Block”Considerations - Sequence 1. Output Power : 2. Input Power : 3. Average Input Currents : 4. Input Peak Current ; 5. Selection the Power Switches and Rectifiers (*1) 6. Estimation Component (Optional) (*2) Bio. Medical Instrumentation Lab. , BME, Yonsei
(*1) Selection the Power Switches and Rectifiers Bio. Medical Instrumentation Lab. , BME, Yonsei
(*2) Estimation Component (Optional) Bio. Medical Instrumentation Lab. , BME, Yonsei
Epilogue – Q&A Thank you for your attention ! Bio. Medical Instrumentation Lab. , BME, Yonsei
- Circuit switching vs packet switching vs message switching
- Smps power plant
- Display modes in ultrasound
- Virtual and datagram networks
- Cell switching vs packet switching
- Circuit switching disadvantages
- Virtual circuit switching example
- Cell switching vs packet switching
- What is smps in telecom
- Smps simulation
- Block diagram of smps
- Flybacks
- Conduit liner welding definition
- Commercial power supplies
- Tactical power supply
- Power electronics
- Diode symbol
- Draw the power triangle
- Focus mode and diffuse mode
- Mode địa chỉ tức thì là mode
- Difference between real protected and virtual mode of 80386
- Timer in 8051
- Gartner mode 1 mode 2